WATERMAKER GROUP. 

 

 
 
 
 
 

 
 
 
 
 
 

 
 

1.

 

Reverse osmosis membranes 

2.

 

Manometer 

3.

 

Flow meter 

4.

 

Depressurization valve 

 
The watermaker group is constituted of the following components: 

 

 

The Reverse osmosis membranes

, inside the silver high-pressure vessel  are used to separate the 

intake high-pressure seawater into two flows: one for the salt-water waste and one for fresh water 
production. 
 

Energy  Recovery  System

.  Amplifies  the  pressure  supplied  by  the  pump  and  recovers  the 

hydraulic  energy  back  from  the  membranes.  The  ERS  device  makes  periodic  cycling  by  a 
hydraulically  controlled  automatic  valve.  The  cycles  are  noticeable  through  a”  beat”  issued 
periodically by the watermaker unit. The unit contains two cylinders, and a central body housing 
the hydraulic valves.  

 
Manometer

 is located on the front panel, and it measures the running pressure of the pumps.

  

 
Flowmeter

 is located on the front panel, and measures the flow of produced fresh water coming 

out of the unit. This is only indicative  as the accuracy of the flowmeter is +/- 20%. 

 

Depressurization valve

.  Is used only during the air bleeding phase, at the first plant start-up. 

This is a blue lever located to the right side of the watermaker. Its function is to depressurize 
the  system  and  allow  air  bleeding.    The  valve  remains  closed  during  normal  working 
conditions  and  is  opened  only  during  the  air  bleeding  operations.  The  lever  need  only  be 
opened halfway (45°) during air bleeding operations. 

 Positioner

: A stainless steel threaded arm, with a black knob, located on the right side of the 

unit.  Its  function  is  to  reset  the  unit  in  start  up  failure  when  the  unit  has  been  stopped  in  the 
exact centre of a cycle. This will only happen with units fitted with a manual flushing system or 
when the bypass is activated when fitted with an Analogue control

 

Reset  valve. 

The  valve  must  be  closed  during  normal  functioning  (lever  perpendicular  to  the 

valve).  Such  valve  has  the  function  to  allow  the  reset  in  case  of  a  system  block.  It  must  be 
opened before acting on the valve positioner. 
 

Содержание MODULAR 30 digital

Страница 1: ...aterial required 2 2 Components mounting 2 3 Water intake 2 4 Hydraulic connections 2 5 Electric connections 3 Operating procedures 3 1 Remote panel commands 3 2 First start up procedure 3 3 Normal op...

Страница 2: ...Y RECOVERY SYSTEM which amplifies the pressure of common low pressure pumps and recoups all the hydraulic energy back from the membrane This saves on the use of power allowing the Modular 60 to be run...

Страница 3: ...weight 7 Kg Connections Seawater intake holder for hose int diam 16 mm Salt water outlet holder for hose int diam 16 mm Filter 5 micron polyestere pleated type Power supply 12 Vdc 20 version 30M12 24...

Страница 4: ...et pressure The movement required is very small 1 4 turn 1 BAR This action will not be required in normal circumstances as the unit has been pre calibrated at the factory Before changing the settings...

Страница 5: ...roduced fresh water coming out of the unit This is only indicative as the accuracy of the flowmeter is 20 Depressurization valve Is used only during the air bleeding phase at the first plant start up...

Страница 6: ...protected from water It is connected to the remote panel and controls the functions of the watermaker automatically The microswitches P1and EV allow the direct command of the pump the electrovalve res...

Страница 7: ...ht when the filter housing is full of water It may be necessary to create a suitable wooden or fiberglass structure for the unit if an existing one not available The base of the pump is equipped with...

Страница 8: ...must be secured with double hose clamps It is not advisable to Tee into the engine cooling water intake as it may impair the cooling of the engine An easily inspected mesh type filter will be require...

Страница 9: ...einforced hose An inadequate hose could burst jeopardizing seriously the safety of the boat The hydraulic connections are Low pressure max 3 bar connections sea water inlet net filter backflow valve i...

Страница 10: ...rantee a water head PRODUCTION FRESH WATER CONNECTION The connection has to be made using the small hose supplied with the equipment The connection has to be made between the polyethylene pipe that co...

Страница 11: ...able below Voltage Automatic Cable lenght switch up to 3 mts 3 7 mt 7 10 mt Volt Ampere mm2 AVG mm2 AVG mm2 AVG 12 16 4 11 10 7 16 5 24 10 2 5 13 4 11 4 11 Electric cables and switches selection table...

Страница 12: ...12 Wiring connection diagram Signal pressure switch Electrovalve...

Страница 13: ...uddenly It awaits for the correct positioning of the internal valve 2 3 seconds and then stops automatically If the automatic washing is activated washing light on the system once pushed STOP will per...

Страница 14: ...cartridge replacement or a general service The procedure allows to purge completely the air from the system and from the seawater and the washing fresh water hoses The depressurization valve must be...

Страница 15: ...rge out the air from the system It can be used as well after a filter replacement or after other maintenance operations Preliminary checks Verify that all components are connected correctly Verify tha...

Страница 16: ...row the specific timer menu the system will hold as well the previous setting Push the button START for more than 3 seconds The display will show the decreasing production time The system will stop af...

Страница 17: ...n to jam again resulting in a typical start stop noise After approx 20 sec the computer recognize the problem and turn off the pumps and the message WARNING SYSTEM BLOCKED is displayed This event besi...

Страница 18: ...efully following the indications on the pack Wear a protection mask in order to avoid inhaling product dusts The water temperature doesn t have to be lower than 25 C preferably 3 Close the grey valve...

Страница 19: ...e the filter holder Active carbon filter replacement Every 6 months Close the grey valve before open the filter Purge periodically the air from the system opening at 45 for a couple of minutes the dep...

Страница 20: ...5 Bar Cold sea water Filter clogged Dirty membranes Normal operation Clean filter Perform cleaning cycle Leaking in the plant Loose connectors ERS loss Tighten connectors Contact a service point Prob...

Страница 21: ...S Unless the correct cleaning procedures are carried out in accordance with this manual there may be bacteria present in the produced water Therefore avoid drinking the water produced by the plant if...

Страница 22: ...Service Point or our factory will be on customer account The under guarantee delivered parts transport will be at customer s own risk In case of repairs under guarantee directly performed by our techn...

Отзывы: