SCHEMPP-HIRTH FLUGZEUGBAU GmbH., KIRCHHEIM/TECK
Ventus-2cM
FLIGHT MANUAL
2.5
Power plant instrument markings
Power plant instrument markings and their colour code significant are shown
below:
Instrument
Normal Range Caution
Range
Maximum
Limit
Signal
green
Yellow
red
Tachometer
RPM-Indicator *)
- min
-1
Range
2500 - 6200
6300 - 6700
6800
(flashing)
Signal
--- --- ---
Coolant Liquid
Temperature
Indicator *)
- °C
Range
40 – 110
---
110
(flashing)
Signal
--- yellow ---
- 9
8 – 0
Fuel Quantity
Indicator *)
LTR
Range
tanks in wing
and fuselage
fuselage tank
only
---
*) Indicated by the ILEC multi-function engine control unit
November
2003
LBA-app.
Revision --
2.5
Содержание Ventus-2cM