Operating and Installation - Battery Charger LAS 1218 BUS
18
Date: 21.11.2018
8100532 BA / EN
2.3.2 Mains connection
Y
DANGER!
230V units carrying mains voltage.
Risk of fatal injury due to electric shock or fire:
F
Only carry out electrical work once the 230V supply has been discon-
nected.
The mains must be connected as follows:
F
to a insulated distribution unit with protective contact
F
to a socket with protective contact (isolated ground or suitable plug
connector from WAGO
, depending on LAS 1218 BUS variant).
The power cord must be of type H05VV-F 3x1.5.
The mains cable must have a strain relief where required.
2.4 Initial use
2.4.1 Checks prior to initial use
Ensure that the batteries are connected properly (only for initial use, ope-
ration without battery is possible in general).
2.4.2 Setting battery type
Determine the battery type
Y
DANGER!
Incorrect setting of the battery selector switch.
Risk of explosion from build-up of electrolytic gas, defective battery, defec-
tive battery charger or as a result of too high a battery operating tempera-
ture (above 305 C):
F
Move the battery selector switch to the correct position.
Store batteries in a place that is sufficiently ventilated (or provide integra-
ted ventilation). Follow the instructions provided by the battery manufac-
turer.
Fig. 8
Battery selector switch
Mains connection
Prior to use