Operating Instructions Booster WA 121545
15
Date: 21.09.2017
8200510 BA / EN
7.5 Booster connector for directly on batteries with additional
chargers
Battery 1
+
--
Battery 2
+
--
70 A
Temperature sensor
Leisure area
battery
Starter
battery
2 A
G
D+
B--
B+
Generator
50 A
16 mm
2
0.
75
mm
2
16 mm
2
16 mm
2
16
mm
2
Temperature and voltage sensor
Voltage sensor
”Bypass” switch in ”Off”
position (see Section 8.4.4)
Set the maximum output
current (”Max. Output”)
appropriate for the fusing
(see Section 8.4.3).
1 A
1 A
to
80 A
+ WB
-- GND
+ SB
Alternative:
Input
additional charger (e.g. solar)
Output
Voltage sensor SB
Fig. 9
Vehicles without Schaudt EBL -- direct connection to batteries
7.6 Connecting the temperature and battery sensor (optional)
The booster is able to control charging of the leisure area battery by tempe-
rature. The optional temperature sensor is required for this.
This function is enabled automatically when the battery temperature sensor
is connected.
"
Connect the temperature sensor to the negative terminal of the leisure
area battery.
"
Route the temperature sensor cable through the vehicle to the booster.
"
Plug the connector into the booster (Figure 10, Pos. 1).