1
3
2
Installation and Setup
7
Instruction Manual
SK12240U3KOC-LB
shar
ed_Installation-Electric_USB3_ML.indd
Instruction Manual SK12240U3KOC-LB © 2020-03 E
2.2 Electrical Installation: Connections and I/O Signals
All
Schäfter+Kirchhoff
USB 3.0 line scan cameras can be operated with a USB 2.0 interface. Note that there might be
limitations in terms of the maximum data transfer rate. The details for your camera can be found in section
Scan Camera - Specifications (p. 5)
If the power consumption of the camera exceeds 4.5 Watt (USB 3.0) or 2.5 Watt (USB 2.0), then connect an external
source to socket
2
.
Accessories
:
Combined Synchronization and Power Cable SK9016.1.5
Use this cable to feed external synchronization signals
and
supply voltage into socket
2
.
Connectors:
Hirose plug HR10A, female 6 pin (camera side)
Lumberg SV60, male 6-pin connector (for supply voltage)
Phoenix 6 pin connector incl. terminal block (for synchronization signals)
Standard length 1.5 m
Power Cable SK9015.xMF
Use this cable to feed external supply voltage into socket
2
.
Connectors:
Hirose plug HR10A, female 6 pin (camera side)
Lumberg SV60, male 6-pin connector (for supply voltage)
Length 1.5 m (standard) or 0.2 m
USB 3.0 cable SK9020.3
For connecting socket
1
with the PC or USB hub. Standard length 3.0 m
Power Supply Unit PS051515
Input: 100-240 VAC, 0.8 A, 50/60 Hz IEC 320 C14 coupler
(for IEC C13 power cord)
Output: +5V DC, 2.5 A / +15 V DC, 0.5 A / -15 V DC, 0.3 A
Cable length 1 m, with Lumberg connector KV60, female 6-pin
(for power cable SK9015.x or SK9016.x)
2
1
3
4
5
6
7
8
9
10
11
12
2
1
3
4
5
6
Synchronization and power *
Power: 5.5 W
Socket: Hirose series 10A, male 6-pin
2
Pin
Signal
Pin
Signal
1
Line Sync B
4
+5 V *
2
+15 V *
5
Line Sync A
3
Frame Sync
6
GND
* from external power supply unit
Line Sync A/B and Frame Sync: TTL levels
3
Status indicator
off
no power, check connection to the external power
supply unit
red
power on
green power on, firmware is loaded, camera is ready
•
The USB 3.0 interface provides data transfer, camera control and power supply capabilities to the
SK12240U3KOC-LB line scan camera. The operating power can also be fed into socket
2
. This is only
mandatory when the camera is operated at 60 MHz or when it is connected to an USB 2.0 interface.
•
If you want to operate the camera in FREE RUN trigger mode the connection is completed with the USB 3.0
cable provided the power supply is ensured.
•
For any kind of synchronized operation the external trigger signal(s) have to be wired to socket
2
in addition.
A frame synchronization signal and two separate line synchronization signals can be handled. The various
trigger modes are particularly described in section
Synchronization of the Image Acquisition with the Feed
1
Data and power
USB 3.0 socket type µB with threaded holes for locking screws