Installation and Setup

Instruction Manual

 SK12240U3KOC-LB

 

 

  

shar

ed_Installation-Mechanic_Axx-BGx_ML.indd

6

Instruction Manual SK12240U3KOC-LB    © 2020-03 E

Installation and Setup

2.1  Mechanical Installation: Dimensions, Mounting Options, and Heat Dissipation

Casing type AT3L

Mounting Options

When mounting the camera, pay attention to the 

following: 
•  Mechanical stability to avoid vibrations.
•  Good thermal coupling for cooling the housing. 

The power consumption and the maximum 

housing temperature of the camera are specified 

in section 

1.4 - Specifications

.

The best fixing point of the camera is the collar for 

the mounting bracket SK5105-L (available as an 

accessory).
Four threaded holes M3 x 6.5 mm provide further 

options for customized brackets.
The length and weight of the optics might be beyond 

the capability of the standard mounting bracket 

SK5105-L. For this purpose, a second mounting 

bracket type SK5105-2L to hold the tube extension 

ring(s) is more appropriate.

Optics Handling

•  If the camera and the optics are ordered as a kit, 

the components are pre-assembled and shipped 

as one unit. Keep the protective cap on the lens 

until the mechanical installation is finished.

•  If you must expose the sensor or lens surface, 

ensure the environment is as dust-free as 

possible. 

•  Gently blow off loose particles using clean 

compressed air.

•  The sensor and lens surfaces can be cleaned with 

a soft tissue moistened with water or a water-

based glass cleaner.

Mounting bracket SK5105-L

Mounting system SK5105-2L

for cameras with a tube 
extension > 52 mm

Clamping set SK5101

Set of 4 pcs. clamping claws incl. hex 
socket screws (EN ISO 4762–M3x12)

66

10 10

36

M3

Ø3.3

6

50

.3

41

.7

Ø 47

.5

50

20

16.5

3.5

6.5

Ø4.3

15

M4

1/

4’’

 20G

40 63

70

6

36

Ø 47.5

70

3.5

31.5

25

10

3.5

70

63

40

1/

4’

’ 20G

M4

Ø4.3

Содержание SK12240U3KOC-LB

Страница 1: ...ine scan camera SK12240U3KOC LB mounted with 2 Mounting bracket SK5105 L 3 Clamping claws SK5101 4 Focus adapter FA22R 45 two piece facilitates adjustment of any rotation angle 5 Enlarging lens Apo Ro...

Страница 2: ...look directly into the light beam Mechanics Warning Ensure that the motion device and the scan way is free to move and that no obstacles are in the way Do not place any part of the body in the way of...

Страница 3: ...p 8 Camera Setup 8 Initial Function Test 9 3 Camera Control and Performing a Scan 10 3 1 Software SkLineScan 10 Function Overview SkLineScan Toolbar 10 Visualization of the Sensor Output 11 3 2 Adjust...

Страница 4: ...CD then the camera can be parameterized The parameters such as integration time synchronization mode or shading correction are permanently stored in the camera even after a power down or disconnectio...

Страница 5: ...led so that the acceptable casing temperature is not exceeded during operation Therefore applies to the thermal resistance of the bracket or heat sink amb casing RthHS Pcamera where RthHS K W thermal...

Страница 6: ...be beyond the capability of the standard mounting bracket SK5105 L For this purpose a second mounting bracket type SK5105 2L to hold the tube extension ring s is more appropriate Optics Handling If t...

Страница 7: ...Power Supply Unit PS051515 Input 100 240VAC 0 8A 50 60Hz IEC320 C14 coupler for IEC C13 power cord Output 5VDC 2 5A 15VDC 0 5A 15VDC 0 3A Cable length 1m with Lumberg connector KV60 female 6 pin for p...

Страница 8: ...the downloaded zip file to a temporary folder Alternatively if your installation medium is a CD insert the disk to the drive The autostart function may launch the setup program automatically from CD O...

Страница 9: ...n Software_USB3 indd Instruction Manual SK12240U3KOC LB 2020 03 E Initial Function Test Quit the SkLineScan startup dialog box Select OK in the SkLineScan start up dialog The Signal Window showing the...

Страница 10: ...am The SkLineScan program recog nizes the connected line scan cameras automatically The identified cameras are shown in the start up dialog A If the SK12240U3KOC LB camera is identified correctly conf...

Страница 11: ...e sensor Platzhalter f r Grafiken in anderen Ebenen Zoom Function With a high number of sensor pixels details are lost due to the limited number of display pixels With the zoom function you select a p...

Страница 12: ...litates the effective focussing of the line scan camera system even for two dimensional measurement tasks For determining the correct focus the edge steepness at dark bright transi tions and the modul...

Страница 13: ...the other Offset sliders A slight signal noise should be visible in the zero baseline 2 Gain Illuminate the sensor with a slight overexposure in order to identify the maximum clipping Use the Gain sli...

Страница 14: ...orrection with a balanced RGB sensitivity ensures a natural color reading The reference signal is stored in the Shading Correction Memory SCM of the camera and subsequent scans are normalized using th...

Страница 15: ...m brightness adjustment Integration Time p 17 Check that the weakest color signal is higher than about 70 If necessary adjust the line frequency or the illumination intensity accordingly Tick the box...

Страница 16: ...th FL sensor length SL and field of view FOV according to your setup The implemented algorithm will compensate the natural lens vignetting Click on Save SCM to Flash to save the SCM reference signal i...

Страница 17: ...is setting optimum signal sensitivity is achieved and overexposure or even blooming is avoided Open the Camera Control dialog Menu Edit Operation Parameters or F4 The integration time can be set by tw...

Страница 18: ...rchhoff contain easy to use functions for this purpose If the object speed is variable or the accuracy requirements are high external synchronization is required The various synchronization modes are...

Страница 19: ...of the exposure are controlled internally by the camera and are not affected by the trigger pulse The exposure time is programmable The line frequency is determined by the frequency of the trigger si...

Страница 20: ...ameras trigger Restart SOS discharge Line Sync B LVAL Camera Interface SynC 3 7 Sync Divider M3 Region of Interest ROI pixel clock Functional diagram of the Camera Control System Camera Control dialog...

Страница 21: ...ronous object transport B asynchronous transport of the object causes color convergence aberration The Camera SK12240U3KOC LB outputs the green G red R and blue B information se quentially in one sing...

Страница 22: ...ific product information can be read from the camera using the request commands All set and request commands are listed in the tables below The commands are entered in the Input field in the Camera Co...

Страница 23: ...R extern sync divider yyyyy 1 32767 Yppp CR set sync control ppp 255 SCOG CR enable COG coupling of gain settings RCOG CR disable COG coupling of gain settings SDXT CR enable DXT decoupling of line cl...

Страница 24: ...unction 0 x x x x x x x Sync Control Enable 1 x x x x x x x 128 64 32 16 8 4 2 1 For diagnostic purposes the present state of external trigger inputs LINE SYNC A LINE SYNC B FRAME SYNC or the internal...

Страница 25: ...00xxx b C 1 Trigger on 4 edges of SyncA and SyncB direction detection off hysteresis 0 Sync Control Register 11100xxx b D 1 Trigger on 4 edges of SyncA and SyncB direction detection off hysteresis 4 S...

Страница 26: ...red_Sensor_KLI 4104_ML indd 26 Instruction Manual SK12240U3KOC LB 2020 03 E 5 Sensor Information Manufacturer TRUESENSE Imaging Inc Type KLI 4104 Data source KLI 4104 Image Sensor Device Performance S...

Страница 27: ...uction Manual SK12240U3KOC LB shared_Sensor_KLI 4104_ML indd 27 Instruction Manual SK12240U3KOC LB 2020 03 E b Imaging Performance Imaging Performance Operational Conditions Imaging Performance Specif...

Страница 28: ...formation Instruction Manual SK12240U3KOC LB shared_Sensor_KLI 4104_ML indd 28 Instruction Manual SK12240U3KOC LB 2020 03 E Imaging Performance Specifications Luma Channels c KLI 4104 Image Sensor Res...

Страница 29: ...Sensor Information Instruction Manual SK12240U3KOC LB shared_Sensor_KLI 4104_ML indd 29 Instruction Manual SK12240U3KOC LB 2020 03 E d Defect Pixel Classification e Notes...

Страница 30: ...ixels 24 Test 24 Dark ea 8160 Active Luminance Pixels 24 Dark ea 4 Blank ea 2040 Higher order pixels odd 4 Blank ea 4 Blank Pin 1 Corner Chroma Pixel 1 Luma Pixel 1 Centered on Chroma Pixel 1 Leading...

Страница 31: ...determines the minimum exposure period Line frequency line scan frequency is the reciprocal value of the exposure period The maximum line frequency is a key criterion for line scan sensors as this is...

Страница 32: ...ve to be compatible with each other For more accurate requirements or with a variable object velocity external synchronization is necessary Synchronization of the Imaging Procedure and the Object Scan...

Страница 33: ...79 22525 Hamburg Email info SuKHamburg de Germany Internet www SuKHamburg com This manual has been prepared and reviewed as carefully as possible but no warranty is given or implied for any errors of...

Страница 34: ...a side LumbergSV60 male 6 pin connector for supply voltage Phoenix 6pin connector incl terminal block for synchronization signals SK9016 1 5 Order Code Adapter cable for sync signals CAB ADSync BNC 1...

Отзывы: