6.4 Pump
Danger of property damage
Check the pump support for flatness and avoid tensions
Check the piping for correct installation and avoid tensions due to piping
Ensure that the directions of rotation of the drive and pump match (indicated by
an arrow on the housing or on the rating plate); a left-turning motor, for
example, requires a right-turning pump
Do not tilt the pump shaft and the motor shaft
Do not assemble the coupling parts by hammering or pressing
Observe the permissible tightening torques of the fixing screws (see page 17)
Proceed in the order given:
Step
Procedure
1
Clean the sealing surfaces and check for damage.
2
For hollow shaft connections: Grease the gearing (see page 21).
3
For O-ring sealing: Grease the O-ring.
4
Mount the pump on the
motor shaft.
Correct
Incorrect
Hollow shaft gearing
Correct
Incorrect
5
Before start-up, fill the pump with oil from the suction side.