ERROR CODES
SMS
CAUSE
DELAY
AC Power - FAIL
Power fail: External power supply faulty or disconnected.
15 minutes
AC Power - RESTORED
Power fail: External power supply restored.
15 minutes
Battery - DISCONNECTED
Battery power: Battery switched off or disconnected.
3 minutes
Battery - CONNECTED
Battery power: Battery reconnected.
3 minutes
Battery - LOW
Battery power: Low battery level.
3 minutes
Battery - RESTORED
Battery power: High battery level.
12 hours
Temperature - LOW
Temperature alert: Low temperature level.
3 minutes
Temperature - HIGH
Temperature alert: High temperature level.
3 minutes
Temperature - LOW / RESTORED
Temperature alert: Low temperature level restored.
3 minutes
Temperature - HIGH / RESTORED
Temperature alert: High temperature level restored.
3 minutes
Operating error!
Something wrong with the SMS command.
15 seconds
FACTORY RESET
1. Disconnect external power supply and switch off the battery switch under the service cover.
2. Hold down both buttons on the right side of the unit at the same time as you reconnect the external power supply.
3. When all the lights on the front of the unit flash rapidly, release the buttons on the side.
4. The device is now restored to factory settings.
TROUbLESHOOTING