background image

496368 Issue 1

7 of 12

To change:

Key in: Then:

Notes

Default

Zone Options

5n 

ENTER

1

= Double knock

(n = zone number)

2

= Chime

3

= Auto Restore

Press Clear to clear zone

4

= Entry Route

of any existing options.

5

= Personal Attack

(see note 6)

6

= Entry/Exit

7

= Part Set

8

= Fire

Press  

ENTER 

 after making selections.

Carrier Jamming Detect†

65 

ENTER

Any* 

ENTER

Zone 8 LED shows status

ON

Bell Test

91 

ENTER

Bell sounds for 10seconds (see note 7)

Strobe Test

92 

ENTER

Strobe active for 60seconds (see note 7)

Panel sounder test

93 

ENTER

Panel sounder active for 10secs (see note 7)

Load defaults

98 

ENTER

Leave Programming

99 

ENTER

*Any = press any numbered key to toggle the option on or off. Zone 8 LED indicates

the status of the current selection (LED glowing function ON).

† Not available on earlier versions of software.

Notes:

1. While entering the new password, zone 1 LED flashes.
2. Zone 2 LED glows and zone 8 LED shows the status of the Consecutive
Code Checking function.
3. Zone 3 LED glows and zone 8 shows the status of the Instant Night Mode
(LED glowing-Function ON). Instant Night Mode only affects entry/exit zones
that are also part-set zones. If the mode is ON, part-set entry/exit zones
become instant alarm zones, rather than entry/exit zones during part-set mode
only. If the mode is OFF, the part-set entry/exit zones are entry/exit zones as
normal. This mode has no affect in the full-set mode or on entry/exit zones that
are not part-set zones.
4. Unless Entry Route zones are included, DO NOT select the First Zone
Lockout function, as an entry fault would make it impossible to unset the panel
without first creating an alarm condition.
5. The 4600 system features a two-ply entry time. After the selected entry time
has expired, the system will enter into an internal alarm for a period equal to
50% of the selected entry time. If the panel is not unset by entering a valid
code by the time the 50% extra time has expired, the system will enter into a
full alarm condition (internal sounders/external bell and strobe).
6. If you do not select an option for a zone it becomes a Normal Night zone.
The system will not let you select certain options together, for example: entry
route and PA zone.
You must select Auto restore for PIRs, smoke detectors, Viper detectors, and
PAs.
7. Press Enter to end test prematurely.

4600

Engineering Program Commands

Содержание 4601

Страница 1: ...ipment 4601 Long range and short range pendant transmitters 4602 Hand held PA 4603 Programmable transmitter 4604 Contact transmitter 4605 Short range dual channel transmitter 4608 PIR 4609 Smoke detector 7150 Viper radio vibration detector supplied by Weyrad Elec tronics ...

Страница 2: ... Max 30VA Short circuit protection Outputs short circuit protected for indefinite periods by means of Polyswitches which will recover after removal of short circuit Reverse polarity protection Battery connections are reverse polarity protected for at least 5 minutes Battery back up Back up time panel only with fully charged battery typically 20 hours 12V Lead Acid battery typically 2 1AH Float cha...

Страница 3: ...en or bell The bell siren will continue to ring from the on board battery until the final connections are made after initial power up Programming Programming Detectors A series of six DIL switches on the control panel main printed circuit board enables each system to be identified by means of a different code thereby avoiding the possibility of interference from adjacent systems The site code is u...

Страница 4: ...e user code 1234 to silence the internal sounder The panel is now in DAY mode The walk test and other LEDs may be illuminated but please ignore them at this stage To Enter Programming Mode Make sure the Day LED is glowing before trying to enter programming mode 1 Press 0 then Enter 2 Key in the engineer access code default 7890 3 Open control panel cover to activate the lid tamper switch All panel...

Страница 5: ...the values taken by each com mand The panel gives three short high pitched beeps if it accepts the values you enter If you enter an incorrect value the panel gives a longer lower pitched fault tone When you complete a command correctly the panel flashes all LEDs to show that it is ready for another command Note It is not necessary to program all the options Where a change has to be made to a parti...

Страница 6: ...stant Night Mode 33 ENTER Any ENTER See note 3 OFF Remote Set 34 ENTER Any ENTER Zone 8 LED shows status ON First Zone Lockout 35 ENTER Any ENTER See note 4 ON Part Set Exit Timer 41 ENTER 1 ENTER 10 seconds 2 ENTER 20 seconds y 3 ENTER 40 seconds 4 ENTER 60 seconds 5 ENTER Continuous 6 ENTER Instant 1 5s bleep followed by 20s silent Bell Duration Timer 42 ENTER 1 ENTER 1 5 mins 2 ENTER 3 minutes ...

Страница 7: ...Mode only affects entry exit zones that are also part set zones If the mode is ON part set entry exit zones become instant alarm zones rather than entry exit zones during part set mode only If the mode is OFF the part set entry exit zones are entry exit zones as normal This mode has no affect in the full set mode or on entry exit zones that are not part set zones 4 Unless Entry Route zones are inc...

Страница 8: ... advise you to carry out a walk test 1 Key in 3 then Enter 2 Enter the user code default 1234 The Test LED glows steadily 3 Open or activate each zone in turn The appropriate zone LED glows as you activate the zone The panel gives a loud tone while the zone is open or activated When you close the zone the display shows the next open or activated zone or contin ues to display the last open or activ...

Страница 9: ...isplays Low battery on zone detector Replace battery Jamming present on zone 4 Check for interfering radio signals Activate detector transmitter and enter user code twice If fault persists then call Scantronic product support Zone activated during exit time or during re arm period after an alarm Enter user code twice Tamper on zone active during exit time or during re arm period after an alarm Ent...

Страница 10: ...witch turned on Low battery on remote setting transmitter Replace battery Zone indicated has been activated If the mains fails then the power LED flashes If the battery voltage is low then the power LED goes dark and the panel beeps every 30s When the battery voltage falls below 8V approx then the panel stops operating Fault Finding 4600 ...

Страница 11: ...ad PA 1 3 Silence Bells User code Reset User code Change User Code 6 Enter existing code new code Enter Walk Test 3 Enter User code activate detectors Enter to end test On older units User code 3 Enter activate detectors Enter to end test Chime On Off 4 Enter User code From the 4605UK 55 Remote Setting Device Full Set Press top button Unset Press top button PA Press the two orange side buttons tog...

Страница 12: ...12 of 12 496368 Issue 1 ...

Отзывы: