8 of 12
496368 Issue 1
Leaving Programming Mode
When all programming is complete:
1.
Remove the programming stencil and close the panel.
2.
Key in 99 then Enter.
The panel returns to Day mode.
If faults are present on entering the Day mode, the panel gives a low-high
bleep. Investigate any faults before proceeding. If the control panel does not
go into the Day mode, either the control panel lid or bell cover is open.
Restoring Factory Defaults
1.
Enter programming mode.
All LEDs flash.
2.
Key in 98 then Enter.
The panel loads all the factory defaults.
Note: Using this command will erase all values, including user and engineer codes,
which have been previously programmed. If you have lost the engineer or user
code, you may load the factory default programme by removing all power and
holding down OMIT and 1 while restoring power.
Testing
Walk Test
The system flashes the Walk Test LED after a preset number of operations
to advise you to carry out a walk test.
1.
Key in 3 then Enter.
2.
Enter the user code (default 1234).
The Test LED glows steadily.
3.
Open or activate each zone in turn.
The appropriate zone LED glows as you activate the zone. The panel
gives a loud tone while the zone is open or activated. When you close
the zone the display shows the next open or activated zone, or contin-
ues to display the last open or activated zone if there are no other zones
open.
Note: In normal use the 4608 uses a 2.5 minute lockout time in order to extend
battery life. The lockout timer works as follows:
a) The unit detects movement, signals the panel, and starts the lockout timer.
b) If the unit detects movement while the lockout timer is running, then it
restarts the lockout timer but does not signal the panel.
c) When the lockout timer expires the unit signals the panel the next time it
detects movement.
If you want to test the unit in normal use you should wait at least three minutes
between activations.
On older units, enter user code (default 1234) and then key in 3. The test
LED glows steadily. Carry on from step 3.
Leaving Programming Mode
4600
Содержание 4601