7
2.3 Maintenance
After a period of use it may be necessary Lubricate handle bar with acid-free oil
and adjust the upper knife. The length of this period depends on how many cutting
operations the shears have performed and also the thickness of the plate. It is
also necessary to grease the 2 grease nipples.
When adjusting the upper knife: first dismount the top plate (J) to be able to
dismount the protection plate (K) (see
fig. 2.2)
and also the plate holder (L). Now
loosen the 8 nuts (M) holding the slide bars (N) tightened.
Fig. 2.2
Now the upper knife can be adjusted according to the lower knife so there will be a
knife crack of approximately ca. 0,1 mm (see
fig.: 2.3
). Check this by making a
test cut without plate. Now the nuts can be retightened and the plate holder and
the top and protection plates can be refitted.
J
L
M
N
K