#SC 45TW-SS 10 – 110202
Page 11 of 40
6. Installation Instructions
General Installation Instructions:
The Scanjet SC 45TW cleaning machine
should be installed in vertical position (upright or inverted). It is recommended
to install a filter in the supply line in order to avoid large particles lodging inside
the machine. The portable SC 45TW is fitted with strainers at the inlet. Before
connecting the machine into the system, all supply lines and valves should be
flushed to remove foreign matter.
Cleaning Media:
Only media compatible with the materials listed on the
reference list of parts for your model should be used, see “4. Technical Data”
on page 7.
After Use Cleaning:
Depending on the type of cleaning that is being performed
and the type of cleaning solution used, a procedure for after use flushing of the
cleaning system should be developed for your application. In general, a fresh
water flush is recommended after each cleaning.
Pressure:
Hydraulic shocks may damage the system. In order to avoid shocks
increase pressure gradually from 0 to maximum operating pressure over 5-7
seconds. Do not exceed 14 Bar (200 PSI) inlet pressure. Higher pressure in
combination with higher flow rates will increase consumption of wear parts.
WARNING!
If the machine is
used in potentially explosive at-
mospheres
then tapes or joint sealing compounds, which are elec-
trical insulators, must not be used on threads or joints, unless an
electrical connection is otherwise established to ensure an effective
grounding. In addition, connection pipe work must be electrically
conductive and grounded to the tank structure. This is important in
order to avoid any build up of static electricity in the machine.