4.
A
Side of heater to side wall
425mm
B
Centre of heater flue to rear wall
287mm
C
Rear of heater to rear wall
*175mm
D
Hearth to door hinge
200mm
E
Front of heater to hearth front
300mm
F
Minimum hearth width
820mm
G
Minimum hearth depth
900mm
H
Rear corner of heater to wall
*200mm
I
Minimum Corner Hearth Depth
1250mm
*With decorative flue, with at least 180
O
heat shield
and 900mm 180
O
flue shield in place.
INSTALLATION
CLEARANCES TO COMBUSTIBLES
BEFORE INSTALLING YOUR WOOD HEATER
....continued
CLEARANCES TO COMBUSTIBLES
It is extremely important that you respect required installation distances and that you respect local installation regulations.
This is for your safety! The manufacturer is not responsible for the product, if it is not installed following these recommendations.
These clearances may only be reduced by means approved by the regulatory authority.
A combustible surface is anything that can burn (i.e. plaster, wall paper, wood, fabrics etc.) These surfaces are not limited to those
that are visible and also include materials that are behind non-combustible materials. If you are not sure of the combustible nature
of a material, consult your local fire officials.
HEARTH REQUIREMENTS
The floor protector must consist of 30mm thick cement fibre sheet which has a thermal resistance of 0.008m2 K/W, per 4mm
thickness or equivalent. Scandia have a complete range of suitable ready to install hearth pads for straight wall and corner
installations.