SCAN 45i Скачать руководство пользователя страница 5

5

139234_Rev_A    9.17 .10

General Information

IMPORTANT:  SAVE THESE INSTRUCTIONS.

1.  The installation and repair of this appliance must be 

done by a qualified service person. Failure to properly 

install and maintain this heater could result in an 

unsafe or hazardous installation, which may result in 

a fire, explosion, property damage, personal injury or 

loss of life. 

2.  This appliance should be inspected before use and 

at least annually. More frequent cleaning may be 

required due to excessive lint from carpeting, bedding 

material, etc. It is imperative that control compart-

ments, burners and circulating air passageways of the 

appliance be kept clean.

  `S’assurer que le bruleur et le compartiment des com-

mandes sont propres. Voir les instructions d’installation 

et d’utilisation qui accompagnent l’appareil.

3.  This appliance may be installed in an aftermarket 

permanently located, manufactured (mobile) home, 

where not prohibited by local codes.  

This appliance is only for use with the type(s) of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases, unless a certified 

kit is used. 

  Cetappareil peut être installé dans un maison préfab-

riquée (mobile) déjà installée à demeure si les règle-

ments locaux le permettent.

  Cet appareil doit être utilisé uniquement avec les 

types de gas indiqués sur la plaque signalétique. Ne 

pas l’utiliser avec d’autres gas sauf si un kitde conver-

sion certifié est installé.

4.  The installation must conform to local codes. Your lo-

cal Scan authorized dealer can assist you in determin-

ing what is required in your area for a safe and legal 

installation. Some areas require a permit to install 

a gas burning appliance. Always consult your local 

building inspector or authority having jurisdiction to 

determine what regulations apply in your area. 

  In the absence of local codes, the installation require-

ments must comply with the current National codes. 

In the U.S., these requirements are established in the 

National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, 

the codes have been established in CAN/CGA B149 

Fuel Installation Code. 

  Installer l’appareil selon les codes ou reglements 

locaux, ou, en l’absence de tels reglements, selon les 

Codes d’installation CAN/CGA-B149.

5.  Do not operate this fireplace if any part of it has 

been under water.

  Immediately call a qualified service technician to 

inspect the heater and to replace any part of the 

control system and any gas control which has been 

under water.

  Ne pas se servir de cet appareil s’il a ete’ plonge dans 

l’eau, completement ou en partie.  Appeler un tech-

nicien qualifie pour inspecter l’appareil et remplacer 

toute partie du syste’me de controle et toute com-

mande qui ont ete plonges dans l’eau.

6.  Do not operate the fireplace with the glass front re-

moved, cracked or broken. Replacement of the glass 

should be done by a licensed or qualified service 

person.  Only remove glass for routine service. Always 

handle glass carefully.

  Pour utilisation avec les portes en verre cerifiers aved 

l’appareil seulemend ou. Ne pas utiliser avec des 

portes on verre. 

7.  Notify your insurance company before proceeding 

with installation of this fireplace.

THIS HEATER MUST BE INSTALLED AND MAIN-

TAINED BY A QUALIFIED SERVICE AGENCY.  
DO NOT ATTEMPT TO ALTER OR MODIFY THE 

CONSTRUCTION OF THIS APPLIANCE OR ITS COM-

PONENTS. ANY MODIFICATION OR ALTERATION 

WILL VOID THE WARRANTY, CERTIFICATION AND 

LISTING OF THIS APPLIANCE.

NOTE: Installation Requirements for the 

Commonwealth of Massachusetts

1.   If there is not one already present, on each 

floor level where there are bedroom(s), a 

carbon monoxide detector and alarm shall 

be placed in the living area outside the 

bedroom(s). The carbon monoxide detector 

shall comply with NFPA 720 (2005 Edition).

2.   A carbon monoxide detector shall:  

a)  Be located in the room that houses the 

appliance or equipment;

  b) Be either hard-wired or battery powered or 

both; and

  c)  Shall comply with NFPA 720 (2002 Edition).
3.   A Product-approved vent terminal must be 

used, and if applicable, a Product-approved 

air intake must be used. Installation shall be 

in strict compliance with the manufacturer’s 

instructions.  A copy of the installation 

instructions must remain with the appliance 

or equipment at the completion of the 

installation.

Содержание 45i

Страница 1: ...l Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trou vant dans le b timent o vous trouvez Appelez imm diatement votre fournis seur de gaz depuis un voisin Suivez les instructions...

Страница 2: ...ucts be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURN...

Страница 3: ...the glass out of the way 5 The Starfire Glass Embers or Tumbled Stone burner media is packaged separately from the insert firebox Figure 1 Pull each Trunk Latch down to disengage it from the Glass Fr...

Страница 4: ...an 45i gas fireplace insert has been tested and listed as a direct vent gas fireplace heater and listed to ANSI Z21 88 2009 CSA 2 33 2009 CAN CGA 2 17 M91 and CSA P 4 01 2 for Canada Starfire Glass Em...

Страница 5: ...ve been established in CAN CGA B149 Fuel Installation Code Installer l appareil selon les codes ou reglements locaux ou en l absence de tels reglements selon les Codes d installation CAN CGA B149 5 Do...

Страница 6: ...ace Never burn any solid materials wood cardboard paper coal etc in this gas fireplace Use with natural gas or propane fuel ONLY Any safety screen glass or guard removed for servicing the appliance mu...

Страница 7: ...tallation of the brackets allows the insert to be raised up to 2 1 2 off of the hearth Also note that use of the leveling brackets will affect required minimum clearance to combustible top trim and ma...

Страница 8: ...18 forward of the firebox glass panel Raised Hearth A raised hearth that is at least 6 high requires a non combustible hearth that extends a minimum 12 from the fireplace glass and and is a minimum o...

Страница 9: ...ment This appliance requires 120 V AC power to operate the blower accent lamps and electronic ignition Four AA batteries provide back up power in case of a power outage Leg Leveler Bolts and Brackets...

Страница 10: ...3 M99 TEST METHODS AND RESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Vent Guidelines All vent compo...

Страница 11: ...into the chimney flue and ultimately into the intake duct to the insert 9 Compress the ducts so that they are hanging above the height of the fireplace opening and are out of the way 10 Position the i...

Страница 12: ...ESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Figure 9 Venting through prefabricated fireplace chimn...

Страница 13: ...ut holes for both the intake and exhaust liners in the block off plate C A direct vent cap is still required to allow fresh air into the chimney flue and ultimately into the intake flex and insert D A...

Страница 14: ...13 85 WC NECESSARY MANIFOLD PRESSURES inches water column MIN MAX NATURAL GAS 1 6 WC 3 5 WC PROPANE 5 3 WC 11 0 WC ALWAYS TEST PRESSURE WITH THE VALVE REGULATOR ADJUSTED TO THE HIGHEST SETTING Figure...

Страница 15: ...ilot rectification and or frequent burner outages Little variation in flame picture between HI and LO regulator settings Insufficient gas to support more than one ap pliance causing nuisance outages o...

Страница 16: ...BLIS DANS LES IN STRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L EQUIPEMENT Conversion Kit LP 157249 NG 157250 Tools required 1 2 13 mm open end wrench or deep well socket Torx T20 driver 1 4 nut driv...

Страница 17: ...ocated it should not be able to move to the right or left 10 Replace the variable regulator on the gas control valve Using a Torx T 20 screwdriver remove the two screws from the regulator tower on the...

Страница 18: ...aller and applied to the appli ance at the time of the conversion See fig 19 Derating procedure 1 Turn off gas supply to the appliance and disconnect from electrical power source 2 Remove the Glass Fr...

Страница 19: ...ening the air shutter will generate a flame that is blue and transparent or an anemic flame This flame is generally more efficient but not very attractive We recommend the following settings for the S...

Страница 20: ...shutter See figs 14 and 15 pages 16 17 4 Use a 10 mm socket to remove the left and right burner bracket nuts Remove the Burner Bracket from the firebox See fig 23 5 Bend the two upper rear tabs down...

Страница 21: ...ure 26 Install Glass Embers Tumbled Stones Kit 157245 NOTE Install the optional Reflective Glass Panels before installing the stones Spread the stones evenly around the burner media tray CAUTION Take...

Страница 22: ...Figure 28 At the thermostat the two wires should be connected to the two connection screws on the thermostat base plate according to the manufacturer s instructions For the thermostat to function the...

Страница 23: ...e Backing Plate or Trimmable Backing Plate See fig 31 Starting at the small precut slot use a straight edge to draw a guideline across the leg Use a disk grinder to cut off the excess material and fil...

Страница 24: ...there is no call for heat Ideal for use with thermostatic or remote control this feature ignites the pilot flame only when there is a call for heat A battery back up permits continued use in the event...

Страница 25: ...not lifting or float ing The flame should be blue in color around the pilot hood with traces of yellow toward the outer edges It is important that the pilot flame engulf the top 1 8 of the flame recti...

Страница 26: ...s and particulate accumulation may appear on the inside surface to the glass Use a dampened soft cloth to clean the glass and polish with a dry soft towel Specially formulated ceramic glass cleaner ma...

Страница 27: ...214 Screw 8 X 1 4 Taptite SLHWH SZPL 21 223980 ProflameValve Manual Hi Lo NG 22 223215 Adaptor Straight Brass 3 8 NTP x 3 8 Dia Flare 23 129707 Flex tube w connectors 3 8 O D x 24 24 222280 Gasket Dro...

Страница 28: ...Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 SL Blk Oxide 2 222799 Blower Bracket 3 222072 Blower TransFlow 12 Cage 120 CFM No Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 SL Blk...

Страница 29: ...rs Simpson Dura Vent Inc P O Box 1510 Vacaville CA 95696 1510 800 835 4429 Selkirk Corporation 1301 W President George Bush Hwy Suite 330 Richardson TX 75080 1139 800 992 8368 American Metal Products...

Страница 30: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Страница 31: ...ouch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone If your gas supplier cannot be reached call the fire department 1 Set the...

Страница 32: ...ion it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification color or ty...