background image

1

General information

SC 1500 - Doc. No. 018522-000/03-025

GB

General information

SCAN COIN AB reserves the right to revise and improve its 
products as it sees fit. This publication describes this product at the 
time of publication and may not reflect the product at all times in 
the future.
This publication, or parts thereof, may not be reproduced in any 
form, by any method, for any purpose other than the purchaser’s 
personal use, without the express permission of SCAN COIN AB, 
Sweden.

Declaration of conformity

We, SCAN COIN AB, Malmö, Sweden, declare under our sole 
responsibility, that the product in this manual, to which this 
declaration relates, is in conformity with the following standards or 
other normative documents: 
• EN 60 950: 1992; 
• EN 50 081-1: 1992; 
• EN 50 082-1: 1992, 

following the provisions of Directive:
• Low Voltage Directive 73/23/EEC and amending Directive 

93/68/EEC; 

• EMC Directive 89/336/EEC and amending Directives 

92/31/EEC and 93/68/EEC.

Responsibility

The supplier of the equipment accepts no responsibility for injury or 
damage to personnel or equipment, if the equipment is altered in any 
way or used in a manner for which it was not intended at the time of 
delivery. If the conditions for use of the equipment are changed, the 
supplier must be contacted or the declaration of conformity is 
invalidated.

Содержание SC 1500

Страница 1: ...IT ES User s Guide Bruksanvisning Bedienungsanleitung Manuel d utilisation Instrucciones para el usuario Manuale dell operatore SCAN COIN xxx Machine Type SCAN COIN 1500 Currency Counters Doc No 01852...

Страница 2: ...ction Nordic environmental label Detta dokument r tryckt p milj m rkt papper Dieses Dokument ist auf umweltschonend hergestelltem Papier Gedr ckt Ce document est imprim sur du papier conforme aux norm...

Страница 3: ...rency Counters General information 1 Declaration of conformity 1 Responsibility 1 Safety precautions 2 Introduction 3 Accessories 4 Machine part terminology 5 Positional references 6 Installation 6 Ma...

Страница 4: ...tion 13 Setting note density IP 13 Setting UV detection sensitivity UV version only 14 Setting counting speed SP 14 Setting counting speed SET 15 Setting automatic start On Off MN 15 Setting MG MT IR...

Страница 5: ...sole responsibility that the product in this manual to which this declaration relates is in conformity with the following standards or other normative documents EN 60 950 1992 EN 50 081 1 1992 EN 50 0...

Страница 6: ...cation in this guide Caution Cautions indicate a hazard to the machine but not a danger to personnel They clearly state the nature of the hazard and how to avoid it They appear at their points of appl...

Страница 7: ...s stated otherwise SC 1500 is light easy to carry and easy to operate By pressing keys on the control panel you can select the machine s various modes of operation SC 1500 has a LCD Liquid Chrystal Di...

Страница 8: ...orts at the rear of the machine The nine pin standard RS 232 serial interface is used for communication with computer The five pin port is used for connecting the remote display RD 7 accessory Accesso...

Страница 9: ...rol panel 1 Control panel 2 Feed table 3 Start sensor 4 Adjustable guides 5 Knob for thickness adjustment 6 Stacker table 7 Stacker sensor 8 Left and right count sensor 1 2 3 4 5 6 7 8 SC 1500 1 2 3 4...

Страница 10: ...chine must be protected by a fuse or a circuit breaker in the electrical circuit The machine must be installed by a authorized SCAN COIN representative Please also note the following when installing t...

Страница 11: ...machine will add each successive counting to the counted total Intelligent processing This function can be used together with other functions The machine will automatically select the correct setting...

Страница 12: ...hanged up to 7 mm see Setting dimension detection accuracy DD function short side on page 12 The factory setting is 4 mm Manual start SC 1500 std only This function can be used together with other fun...

Страница 13: ...remain even if the machine is switched off Magnetic print detection MG versions only Checks for magnetic ink print Can be used for example on US and Euro notes The purpose is to detect suspicious note...

Страница 14: ...xtended security check by means of infrared light It is used to detect suspicious notes documents When a suspicious note document is detected the machine stops at once with a beep tone and CF3 appears...

Страница 15: ...The machine is automatically set to Batch counting mode 0 will appear on the count display and 100 will appear on the batch display 5 Any function can now be selected see Functions on page 7 Counting...

Страница 16: ...the counted notes The counting continues automatically as long as there are notes on the feed table Adding AD 1 Press C to clear the batch number and disable the batch counting mode 2 Press AD AD appe...

Страница 17: ...he display the density range can be set according to the bank notes to be counted Eight levels of note density are provided The factory setting is level 4 Note The IP function will automatically handl...

Страница 18: ...s ST CL Setting counting speed SP Note If the SP key is not available see Setting counting speed SET on page 15 Press SP to select the desired counting speed The display will show L low speed M medium...

Страница 19: ...There are nine different levels available Press numerical keys 1 or 0 to select the desired speed Setting automatic start On Off MN If the MN key is not available the function can be set by means of...

Страница 20: ...is to adjust for most convenient separation of the notes document If the machine stops frequently and displays dbL Turn the adjusting knob slightly counter clockwise to decrease the gap between the fe...

Страница 21: ...counting No need to remove the complete bundle 3d Undersized or oversized note detected Remove the note and press ST CL to continue counting No need to remove the complete bundle dbL Double notes or...

Страница 22: ...the suspicious note only and then press ST CL to continue counting The suspicious note is not included in the counted total JAn Protective stop Press ST CL to continue counting If the machine does no...

Страница 23: ...is a spare fuse Exchange the fuse See Technical data on page 20 Replace the bottom holder Cleaning Sensors There are four sensors which need to be cleaned regularly Use a soft brush Clean the start s...

Страница 24: ...SC 1500 UV 3D MT 018520 302 SC 1500 UV 3D IR 018520 310 SC 1500 UV 3D MG IR 018520 311 SC 1500 UV 3D MT IR 018520 312 Power supply 99 245 V AC Frequency 60 50 Hz Current consumption 40 W Fuse 2 A Coun...