Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.

Please read these instructions carefully before 
commencing any work. 

This unit must be fitted by a competent and qualified 
electrician.

current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without your 
knowledge.

This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the 
connections.

This product is not suitable for dimming.

household waste. Please recycle where facilities exist. 
Check with your local authority or retailer for recycling 
advice.

These products should not be fitted to PIR circuits or short 
duration timed switches.

This product is rated IP20.

Specification

Layout

Wiring

Check that...

You have correctly identified the wires.
The connections are tight.

No loose strands have been left out of the connection 
block.

Voltage: 240V ~ 50Hz

IP rating: 20         

Operating Temperature : 

-5˚C

 to 

50˚

C

Change over Time: Approximately 1s
Battery Specification: 3.6V 1500mAh Ni-Cad
Battery Charge Time: 24 hours
Battery warranty: 2 years

Maintained Wiring: 

Having correctly identified the wiring from your existing light fitting, unscrew the two securing screws on the tabs inside the 
fitting and flip down the gear tray. Pull the wire through the hole and connect to the connection block inside the product in 
the following way:

lit all the time and in the event of a power failure will 
remain on. The unit will charge automatically.

that the source is 

batteries are charging. 

supply, the battery has not been connected properly or 
the internal circuit may have failed.

three months.

lamp in emergency mode checked every six months.

Operation

Existing fittings must be completely removed before 
installation of a new product. Before removing the existing 
fitting, 

carefully note the position of each set of wires

.

screws and cover and set aside. 

is 200mm.

needed, then file the hole until the recessed unit fits 
snugly.

on the back casing of the product for supply of cable.

detailed overleaf.

Installation

recess,  turn  product  to  correct  position  and  rest  onto 
metal side tabs.

is now ready for use.

Commissioning

Fitting/replacing bulbs

PERMANENT LIVE (BROWN)

NEUTRAL (BLUE)

EARTH  (GREEN/YELLOW)

SWITCHED LIVE  

NEUTRAL TERMINAL

LIVE TERMINAL

EARTH TERMINAL

SUPPLY

LIGHT FITTING