3.3. Operating procedure
•
Allow 10 to 15 minutes after lighting to adjust the
control knob to a higher setting, usually (# 2C) setting.
•
When increasing the heat output, move the control
knob only 1 number at a time, allowing 5 minutes
between moves for the flame to re-adjust to new
setting.
•
If the burner stops during operating, immediately turn
off the control knob position “0" (# 2A) and wait until the
burner is completely cool before repeating the lighting
procedure.
3.4. Shutting down
Figure 14
-
Set dial to the (# 2A) position.
-
Allow the flame to burn out completely before opening
the door (# 3).
3.5. Recommendations
•
The adjustment of the stove has been made at the
factory and checked by your installer. In case of trouble
shooting, do the usual maintenance operations. If
problem persists call your installer.
•
This room heater is a high heat producing appliance
and may cause severe burns if touched on the glass
front door, or on top directly over the burner - keep
children away.
•
CAUTION :
Never light the burner if there is any
amount of oil in pot. Clean out oil before lighting.
•
Too much oil in pot may cause a racing : a very high
flame generating vibrations.
In case of racing :
-
Turn off oil supply.
-
Set dial to the “0" position (# 2A, fig. 14, p. 8).
-
Wait until the burner is completely cool before
repeating the lighting procedure.
•
Do not overfire
. If the unit or chimney connector starts
to glow you are overfiring.
3.6. Maintenance of the stove
•
Every week :
operate the de-scaling lever (# 6, fig. 14,
p. 8). Pull the rod, then push the rod in rotating 360
degrees two or three times.
(CAUTION : The rod is HOT).
•
Every 3 or 4 months
: Clean the burner completely.
-
Remove and brush off the parts of the catalyser, using
a soft bristle brush.
-
Loosen any carbon soot from the burner with a putty
knife, and vacuum clean. Ensure that the small air
holes are free of carbon.
-
When replacing the burner, tighten the nuts evenly
and connect the pipe so as to be airtight.
•
At least once a year / End of heating season :
Clean
or replace the oil filters of the oil supply line (# 5, fig. 14,
p. 8) and to change the joint of the de-scaling lever
(rep. A, fig. 15, code 142889) by a professional
installer.
To clean the filter of the float regulator :
-
Set the regulation knob in closed position “0" (# 2A,
fig. 14, p. 8).
-
Turn off the tankvalve or the valve of the oil supply line.
-
Place a small container (or a small rag) under the
regulator filter opening in order to collect the oil
contained in the regulator.
-
Remove the filter cover plate located under the
regulator (# 5, fig. 14, p. 8) with a screwdriver,
-
Remove the tubular filter from the regulator. Clean it
with oil using a soft brush, never a wire-brush.
-
Replace the filter in the regulator, install the cover
plate and secure with the screw.
¤
Use a soft clean cloth to wipe the front glass when the
unit is running at a low burning rate.
¤
When the main door is opened for cleaning, the flame
will be disturb, and turn to a yellow flame. Clean quickly,
but gently. Close the door, the flame will return to a
normal burning position.
¤
Clean all the enamelled panels of the stove with a dry
or slightly damp soft cloth.
DO NOT CLEAN GLASS WHEN HOT.
Technical manual “1038”
9
“Savoy” - ref. 174 08 02
Instructions for user
Figure 15 - The joint of the de-scaling lever