![Savoie 174 08 02 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/savoie/174-08-02/174-08-02_technical-manual_1204221007.webp)
Please note -
Very important
: The adjustments of the
float regulator are very sensitive. The high and the low
setting screws must never be turned more than a 1/4 of
a turn at a time in any direction from their initial setting.
When making any adjustments, allow 3 to 5 minutes
between adjustments to allow burner to stabilize to
previous adjustment before proceeding, if necessary.
2.11.
Chimney draft required
The reading of the draught must be done once the unit
is hot (minimum 30 minutes of use).
Refer to the specifications (page 3) for minimum
draught requirement. The eventual re-fit must be
realized by a qualified engineer.
The adjustment of the draught will be made with the
barometric damper located at the back of the stove (# 1,
fig. 9)
2.12.
Maintenance of the Chimney
Chimney condition should be checked at least once per
year.
If the appliance is regularly used, the chimney should
be swept several times per year, together with the
stovepipe connection section (and also the flue baffles).
-
First remove the flue baffle (fig. 11)
-
The barometric damper (draught regulator # 1, fig. 9)
should be checked at least once per year.
2.13.
Door closing pressure
Figure 12
The closing latch rotates around a pressure screw
positioned cam.
- Remove gently the ceramics rope,
- Loosen pressure screw (# 1),
- Turn cam (# 2) to desired position,
- Tighten pressure screw (# 1).
Technical manual “1038”
7
“Savoy” - ref. 174 08 02
Installation instructions
1
2
Figure 10 - Removing the front grate
Figure 11 - Removing the flue baffle
1
2
Figure 12 - Door closing pressure
1
- Pressure screw
2
- Cam