2.14.

Removing the burner

To remove the burner : Remove the lower panel and the

magnet support, disconnect the feed line from the

de-scaler nut, unscrew the 4 burner fixing nuts.

3.

Instructions for user

Franco Belge will not be responsible for damages on

parts of the appliance due to the use of prohibited fuel

or due to an alteration of the appliance or its

installation.

3.1.

Fuel

Your stove is fitted with a specific float regulator for a

specific oil.
The fuel oil must be free from any dirt and water, which

could disturb the stove in operation.

3.2.

Lighting procedure

Figure 14

Don’t light the appliance when it is hot. Wait until the

burner is completely cool before repeating the lighting

procedure.

-

Be sure the control knob (# 2A) is to “0".

-

Turn on oil supply,

-

Push down gently on the safety lever (# 4). This will

allow the oil to flow into the float regulator.

-

Open the front door, and remove the catalyser from

burner (# 2, fig. 3, p. 4). Make sure the inside of the pot

is clean thoroughly, and there is no oil accumulation.

-

Place 2 tablespoons of methylated spirit or gelled

alcohol in the bottom of the pot.

-

Light the starter gel or methylated spirit with a

fireplace match or long butane lighter.

-

Place the catalyser back into the burner, being sure it

is centered in the burner. Shut the main door.

-

Allow the burner to heat approximately 30 to 45 sec.

Turn dial to “1" position (# 2B).

-

Allow 10 to 15 minutes for oil fire and draught to

stabilize. The catalyser (or the ring) should glow red

before adjusting the control knob to a higher setting

(# 2C).

8

Technical manual “1038”

“Savoy” - ref. 174 08 02

Instructions for user

Figure 13 - Removing the burner

1

2

3

4

5

6

 

)

 

*

 

+

Figure 14 - Operating devices

1

- Gant de protection

2

- Regulation knob.

2A

- Shutting down

2B

- Lighting procedure

2C

- Normal speed

3

- Opening and closing

of the window

4

- Safety lever.

5

- Access to regulator’s

filter

6

- De-scaling lever.

Содержание 174 08 02

Страница 1: ...h the capital of 10 000 000 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM RCS Colmar SIREN 444 881 953 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28...

Страница 2: ...ing the burner p 8 Instructions for user p 8 Fuel p 8 Lighting procedure p 8 Operating procedure p 9 Shutting down p 9 Recommendations p 9 Maintenance of the stove p 9 Trouble shooting p 10 Spare part...

Страница 3: ...3 Optional equipment Visioflamme mirrors Glow plug ignitor Ceramic coals 1 4 Specifications Model 174 08 02 Nominal Heat Output kW 8 at maximum speed liter hr 0 95 at minimum speed liter hr 0 25 Chimn...

Страница 4: ...be carried out according to local building regulations The manufacturers responsibility shall be limited to the supply of the equipment A remote acting fire valve must be fitted on the oil supply line...

Страница 5: ...ector The appliance must be as close as possible to the chimney The connector pipe must be approved for installation with combustion products either 24 ga Black painted or blued steel or 316 grade 20...

Страница 6: ...ses before readjusting the settings Chimney draught Fresh air inlet Oil supply Minimum speed 3 fig 9 Set the regulating knob on minimum speed 3 and let the burner run for a few minutes The flame must...

Страница 7: ...with the barometric damper located at the back of the stove 1 fig 9 2 12 Maintenance of the Chimney Chimney condition should be checked at least once per year If the appliance is regularly used the ch...

Страница 8: ...into the float regulator Open the front door and remove the catalyser from burner 2 fig 3 p 4 Make sure the inside of the pot is clean thoroughly and there is no oil accumulation Place 2 tablespoons o...

Страница 9: ...in rotating 360 degrees two or three times CAUTION The rod is HOT Every 3 or 4 months Clean the burner completely Remove and brush off the parts of the catalyser using a soft bristle brush Loosen any...

Страница 10: ...knob to minimum speed 1 If problem persists call your installer Fire smokes Soot build up noticed Flame imbalance Insufficient air supply Increase fresh air supply open door window add make up air su...

Страница 11: ...26 236511 60 Burner support 01 27 239723 60 Regulator support 01 28 259015 Fixing plate 04 29 260585 Heat shield 01 30 261817 Heat shield 01 31 262220 60 Shield 01 32 262609 Heat shield 01 33 276230...

Страница 12: ...12 Technical manual 1038 Savoy ref 174 08 02 Spare parts Figure 16 Spare parts view 64 65 66...

Страница 13: ...Technical manual 1038 13 Savoy ref 174 08 02 Notes...

Страница 14: ...our technical documents and our installation adjustment instructions 3 The installation use and maintenance of the device carried out in conformity with the applicable standards and legislation and wi...

Отзывы: