![Savoie 174 08 02 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/savoie/174-08-02/174-08-02_technical-manual_1204221008.webp)
2.14.
Removing the burner
To remove the burner : Remove the lower panel and the
magnet support, disconnect the feed line from the
de-scaler nut, unscrew the 4 burner fixing nuts.
3.
Instructions for user
Franco Belge will not be responsible for damages on
parts of the appliance due to the use of prohibited fuel
or due to an alteration of the appliance or its
installation.
3.1.
Fuel
Your stove is fitted with a specific float regulator for a
specific oil.
The fuel oil must be free from any dirt and water, which
could disturb the stove in operation.
3.2.
Lighting procedure
Figure 14
Don’t light the appliance when it is hot. Wait until the
burner is completely cool before repeating the lighting
procedure.
-
Be sure the control knob (# 2A) is to “0".
-
Turn on oil supply,
-
Push down gently on the safety lever (# 4). This will
allow the oil to flow into the float regulator.
-
Open the front door, and remove the catalyser from
burner (# 2, fig. 3, p. 4). Make sure the inside of the pot
is clean thoroughly, and there is no oil accumulation.
-
Place 2 tablespoons of methylated spirit or gelled
alcohol in the bottom of the pot.
-
Light the starter gel or methylated spirit with a
fireplace match or long butane lighter.
-
Place the catalyser back into the burner, being sure it
is centered in the burner. Shut the main door.
-
Allow the burner to heat approximately 30 to 45 sec.
Turn dial to “1" position (# 2B).
-
Allow 10 to 15 minutes for oil fire and draught to
stabilize. The catalyser (or the ring) should glow red
before adjusting the control knob to a higher setting
(# 2C).
8
Technical manual “1038”
“Savoy” - ref. 174 08 02
Instructions for user
Figure 13 - Removing the burner
1
2
3
4
5
6
)
*
+
Figure 14 - Operating devices
1
- Gant de protection
2
- Regulation knob.
2A
- Shutting down
2B
- Lighting procedure
2C
- Normal speed
3
- Opening and closing
of the window
4
- Safety lever.
5
- Access to regulator’s
filter
6
- De-scaling lever.