![Savant CLI-W210 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/savant/cli-w210/cli-w210_deployment-manual_1203683007.webp)
Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x)
7 of 21
45 Perseverance Way, Hyannis MA 02601
009-1959-00 | 200723
| 508.683.2500
1 Stage Heat, 1 Stage Cool, Separate Power Source
o
G
AUX
OUT
AUX
IN
RS2
RS1
GND
GND
R
X-
RX+
GND
1-
WIRE
5V
DC
Y2
Y1
W2
W1
RC
RH
TX+
TX- 24C
W1
1st Stage
Heat
24V AC
120V AC
FURNACE
CONNECTIONS
AIR CONDITIONER
CONNECTIONS
Compressor
1st Stage
Fan Relay
24V AC
R
G
Y1
R
C
C
–
Connect 24V AC from the cooling system to the RC and 24C
terminals.
–
Connect the power from the heating system to the RH terminal.
–
Remove the shunt from jumper JP1 on the thermostat's circuit board.
–
Connect the W1 terminal on the thermostat to W1 in the HVAC
system.
–
Connect the Y1 terminal on the thermostat to Y1 in the HVAC system.
–
Connect the G terminal on the thermostat to the fan in the HVAC
system.
–
Savant recommends using standard #18 AWG HVAC wiring.
HELPFUL!
In both diagrams above, the power source from the cooling system is used to power the thermostat.
2 Stage Heat, 2 Stage Cool, Separate Power Source
o
G
AUX OUT
AUX
IN
RS2
RS1
GND
GND
R
X-
RX+
GND
1-
WIRE
5V
DC
Y2
Y1
W2
W1
RC
RH
TX+
TX- 24C
W1
1st Stage
Heat
24V AC
FURNACE
CONNECTIONS
AIR CONDITIONER
CONNECTIONS
Compressor
1st Stage
Compressor
2nd Stage
2nd Stage
Heat
Fan Relay
24V AC
R
G
Y1
Y2
R
W2
C
C
–
Connect 24V AC from the cooling system to the RC and 24C
terminals.
–
Connect the power from the heating system to the RH terminal.
–
Remove the shunt from jumper JP1 on the thermostat's circuit board.
–
Connect the W1 terminal on the thermostat to W1 in the HVAC
system.
–
Connect the W2 terminal on the thermostat to W2 in the HVAC
system.
–
Connect the Y1 terminal on the thermostat to Y1 in the HVAC system.
–
Connect theY2 terminal on the thermostat to Y2 in the HVAC system.
–
Connect the G terminal on the thermostat to the fan in the HVAC
system.
–
Savant recommends using standard #18 AWG HVAC wiring.