Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x)
16 of 21
45 Perseverance Way, Hyannis MA 02601
009-1959-00 | 200723
| 508.683.2500
8. Basic Configuration Using the On-Screen Menus
This section details the on-screen menus that are available using the thermostat's touchscreen. Use the descriptions below when configuring HVAC control.
Note that Savant recommends connecting the device to the local Wi-Fi network before proceeding. While connection to a network is not required, some
features relying on Internet connectivity are unavailable for devices not provisioned to Wi-Fi.
Select Network To Conect
SKIP
Configure HVAC
System
Edit basic settings for the
HVAC system using this
device or continue using the
HVAC web portal.
ON DEVICE
WEB PORTAL
Temperature Settings
TEMP UNITS
TEMP MAX
TEMP MIN
ENABLED HVAC MODES
HUMIDITY
BACK
NEXT
SKIP
°F
AUTO
HEAT
COOL
OFF
ENABLED
DISABLED
°C
90°
60°
Select System Type
SKIP
NEXT
BACK
SKIP
SKIP
ELECTRIC
GAS
HEATPUMP
RADIANT
Setpoint Type
DUAL
SINGLE
SKIP
NEXT
BACK
ON DEVICE
- Use the on-screen menus to
configure the thermostat with the essential
HVAC settings required for a basic HVAC
system. Use the thermostat's Web Portal when
more advanced programming is needed. A
Wi-Fi connection is recommended but not
required when using the on-screen menus.
TEMP UNITS
- Select either Fahrenheit (F) or
Celsius (C)
ENABLED HVAC MODES
- Available for the Single
Setpoint option only.
HUMIDITY
- Select ENABLED to display the
humidity collected from either the internal
humidity sensor or an external 1-wire smart
sensor like the CLI-THFM1.
TEMP MAX/MIN
- Sets the maximum or minimum
temperature the setpoints can be adjusted to.
AUTO
- The thermostat switches between
heating and cooling based on the room
temperature and the setpoint configured.
HEAT/COOL
-
The thermostat will either only
heat or cool the room based on the room
temperature and setpoint configured.
OFF
- The thermostat won't communicate
with the HVAC system. This button is always
highlighted.
DUAL
- Dual setpoint thermostats incorporate
both a heating and cooling trigger point. The lower
setpoint triggers a call for heat while the upper
setpoint triggers a call for cooling.
SINGLE
- Single setpoint thermostats contain a
single temperature trigger point, and depending on
the temperature in the room, will trigger a call for
heating or cooling.
The single setpoint option incorporates a range
feature that tells the thermostat to keep the room
within a range of temperatures set by the user.
See the
Auto Range
section in the Savant Pro App
HVAC Service User Guide (009-1542) available on
the
ELECTRIC
- Select to control an electric type
furnace. This option dictates that the thermostat
controls the fan and causes the fan relay to switch
on just after a call for heat to ensure air is blowing
once the heating element heats up.
GAS
- Select to control a gas or oil fired type
furnace. This option dictates that the HVAC system
controls the fan when the fan relay is activated.
HEAT PUMP
- Select to control a Heat Pump System.
RADIANT
- Select to control under the floor radiant
type heating system.
IMPORTANT!
The CLI-W200/W210 thermostat can't control an electric
type baseboard or similar device that requires switching either a 120 or
240V AC line voltage on and off.
Set the thermostat to function as either a single or
dual set point
Select the type of HVAC system the thermostat will
be controlling.
WEB PORTAL
- An embedded Web UI used
to configure the thermostat. The web portal
contains all the basic settings from the on-
screen menus, as well as additional advanced
settings not available in these menus. The
thermostat must be connected to Wi-Fi to
access the portal.