Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x)
15 of 21
45 Perseverance Way, Hyannis MA 02601
009-1959-00 | 200723
| 508.683.2500
7.2. Provision To Wi-Fi using the On Screen Display
7. Wi-Fi Network
Connecting CLI-W200/W210 thermostats to the local Wi-Fi network is not a requirement for basic HVAC controller functionality, although it is
recommended since Wi-Fi access adds the following functions:
–
Access to a Savant system.
–
On screen weather forecast
–
Remote Access through a Savant System
–
Over The Air (OTA) updates
The instructions below describe the process for provisioning CLI-W200/W210 devices to the local Wi-Fi network. These steps should be followed
after initially powering the thermostat on, or after resetting the device to factory defaults (due to a change in the local network settings for example).
7.1. Minimum Requirements
1.
Apply power to the thermostat and wait for the
Select Network To Connect
screen to open.
2. Select the network to provision the thermostat to.
3. Enter the password for the network using the on-screen keyboard.
4. Select
DONE
when complete. The thermostat will then verify the network password credentials and connect to the network.
5. From the
Configure HVAC System
screen, select one of the options presented to configure HVAC system settings using the on-screen menus
(for simple configurations) or via the web portal (for more advanced programming).
Select Network To Conect
SKIP
Select Network To Connect
Network 1
Idle Strength: 50 Security: psk
Network 2
Idle Strength: 48 Security: psk
SKIP
Select Network To Conect
SKIP
Configure HVAC
System
Edit basic settings for the
HVAC system using this
device or continue using the
HVAC web portal.
Select Network To Conect
SKIP
Enter Password
<password>
DONE
ON DEVICE
WEB PORTAL
BACK
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
ABC
Select Network To Conect
connected
1
3
5
4
2
ADDITIONAL INFORMATION
–
Static IP addresses are not supported. To configure a specific IP address, Savant recommends DHCP reservation.
–
The Multistat Smart thermostat will not connect to a hidden network (networks not broadcasting an SSID).
–
If the thermostat is reset to factory defaults, the IP information is lost and the thermostat will need to be reconnected to Wi-Fi.
–
Once provisioned to a network with WAN access, the thermostat will query the Savant Cloud and initiate a firmware download when an updated
version is available.
–
Local Wi-Fi network configured and within range - both 2.4 and 5.0 GHz (802.11 b/g/n) are supported.
–
Local Wi-Fi network security - WPA1
™
, WPA2
™
, WPA1
™