TC-BA-e-2020 

 

4. 

Description of the control panel 

 
                 Model TC-F and TC-N                      Model TC-FN (Combi Model) 

     

 

 

 
4-1 Measuring    probe: F, N, or FN

 

4-2    Display 
4-3    Zero key 
4-4    Plus button 
4-5    Minus key 
4-6    On and Off button (multifunctional) 
4-7    µm/ mil Changeover key (shortcut key) 
4-8    Battery compartment / cover 
4-9    S/C measuring mode button (single/continuous) 
4-10    Connector for RS-232C connection 
4-11    F/ NF- key 

5. 

Measuring procedure 

 
a) Switch on by pressing the on/off button 4-6. '0' appears on the display 4-2. 
The TC 1250-0.1FN meter recognizes the setting of the last measurement itself by the 
symbol 'Fe' (= F) for ferrous metals or 'NFe' (= N) for non-ferrous metals shown on the 
display. It switches to the automatic measuring mode, which also correctly recognizes 
and assigns the zero plate or any other substrate itself. 
        
b) Place the measuring probe 4-1 on the layer to be measured. The layer      thickness 
can now be read on the display. The reading result can be corrected by pressing the 
plus key 4-4 or the minus key 4-5. For this purpose, the measuring probe should not 
be in close proximity to the layer to be measured or the zero plate. 
c) To take the next measurement, simply raise the measuring probe 4-1 by more than 

1cm, the display will show "0" again and step b) will be repeated. 

4-10 

4-2 

 4-5 

4-3 

4-4

 

4-1 

4-4 

4-5 

4-6 

4-8 

4-9 

4-8 

4-7 

4-7 

4-10 

4-2 

4-11 

Содержание TC 1250-0.1F

Страница 1: ...2336 Balingen e mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Digital Coating Thickness Gauge SAUTER TC Version 2 0 04 2020 GB TC BA e 2020 PROFESSIONAL MEASURING ...

Страница 2: ...lity of this measuring device and its extensive functionality For any questions wishes and suggestions please do not hesitate to contact us Table of contents 1 Introduction 3 1 1 General description 3 2 Functions 3 3 Technical data 3 4 Description of the control panel 5 5 Measuring procedure 5 6 Zero adjustment 6 7 Battery replacement 6 8 Adjusting foils 7 9 General notes 7 10 Restore factory sett...

Страница 3: ... etc This probe is often used to measure the thickness of galvanized layers lacquer layers enamelled porcelain layers phosphorescent layers copper plates aluminium plates alloys paper etc The N probe measures the thickness of non magnetic layers on non magnetic metals It is used to measure anodizations lacquer layers glazes colours enamel plastic layers powder coating etc These should be on non ma...

Страница 4: ...ries UM 4 Ambient temperature 0 C to 50 C Air humidity 80 Dimensions 126 x 65 x 27mm Weight Ca 81g without batteries Scope of delivery Carrying case operating instructions Depending on the type 1 built in measuring probe F TC 1250 0 1 F with F N key 2 built in measuring probe N TC 1250 0 1 N with F N key 3 built in measuring probe FN TC 1250 0 1 FN without F N u S C key Spacer foils for each model...

Страница 5: ...tself by the symbol Fe F for ferrous metals or NFe N for non ferrous metals shown on the display It switches to the automatic measuring mode which also correctly recognizes and assigns the zero plate or any other substrate itself b Place the measuring probe 4 1 on the layer to be measured The layer thickness can now be read on the display The reading result can be corrected by pressing the plus ke...

Страница 6: ...ressing the on off button 6 Zero adjustment a The zero adjustment for Fe F and NFe N should be done separately The iron zero plate is taken when Fe is read on the display while the aluminium zero plate is taken when NFe is read The measuring probe 4 1 is now carefully placed on the zero plate The zero on off key 4 6 is pressed and 0 is shown in the display without lifting the probe Attention The z...

Страница 7: ...probe should only be carried out by qualified personnel can be carried out 10 Restore factory settings a It is recommended that the factory settings be performed in the following cases no more measurements can be made at all the measuring accuracy is impaired due to drastic changes in the environment in which the measuring instrument is used After replacing the measuring probe b Procedure The fact...

Страница 8: ...ng the on off button It takes about 11 seconds from the beginning of pressing the on off button Its value can be changed by pressing the Plus or Minus key after LN appears in the display and releasing the On Off key The value is stored and then the zero key is pressed A The reading result in the lower area is corrected by pressing the Plus or Minus key B The Ln value is increased if the reading re...

Отзывы: