31
CONNECTIONS SCHEAMTIC
The hot plate is supplied with a power cable.
If the power feed wire is damaged, it must by replaced by the manufacturer,
by the after-sales service or by authorized personnel for safety reasons.
If the type of connections to which the hotplate is to be installed is other than
220 to 240 V Ac rmove the cable and make the connection according to the
adjacent drawings. (The cable must support temperatures of up to 120ºC).
The hotplate must be connected to the mains with a plug that meets the EEC
7 publication or with a multi-pole with a distance between the open contacts
of a least 3 mm.
This device conforms to European directives 73/23/Cee and 89/336/CEE
Total power
Hotplate: 60 cms., 6,3kW
PLATE
60 cms
27,5 A
32 A
220...240V~
14 A
16 A
220...240V~
Three phase
∆
Voltage Tensión
Protection
Int.nominal
by phases
Protección
Int.nominal
por fases
PLATE
60 cms
11 A
12 A
380...400V~
16 A
20 A
380...400V~
Three phase
∆
Voltage Voltage
Protection
Int.nominal
by phases
Protection
Int.nominal
by phases