background image

Gaskookplaat

Table de cuisson

Gas hob

20604 G - 21604 G

11602 G - 21602 G

Gebruiksaanwijzing en Installatievoorschrift
Notice d’utilisation et d’encastrement
Operating and Installation Instructions

 

   

 

NL

FR

GB

Содержание 11602 G

Страница 1: ...Gaskookplaat Table de cuisson Gas hob 20604 G 21604 G 11602 G 21602 G Gebruiksaanwijzing en Installatievoorschrift Notice d utilisation et d encastrement Operating and Installation Instructions NL FR GB ...

Страница 2: ...mustbecarriedoutbyaregisteredCORGIinstaller l Removeallpackagingbeforeusingthehob l Ensurethatthegasandelectricalsupplycomplieswiththetypestatedontherating plate locatednearthegassupplypipe l Donotattempttomodifythehobinanyway Child Safety l Thishobisdesignedtobeoperatedbyadults Donotallowchildrentoplaynearor withthehob l Thehobgetshotwhenitisinuse Childrenshouldbekeptawayuntilithascooled l Childr...

Страница 3: ...be used on the hob as unstable pans can causeanaccidentbytippingorspillage l Neverleavethehobunattendedwhencookingwithoilandfats l Neveruseplasticoraluminiumfoildishesonthehob l Perishablefood plasticitemsandareosolsmaybeaffectedbyheatandshouldnot bestoredaboveorbelowthehobunit Service l This hob should only be repaired or serviced by an authorised Service Engineer andonlygenuineapprovedspareparts...

Страница 4: ...onnection 49 Cut Out Size 50 Building In 50 Building over a cupboard or drawer 50 Building over a kitchen unit with door 51 Fitting the hob to the worktop 52 Electrical connections 53 Permanent Connection 54 Wiring diagram 54 Fault Finding 55 Preliminary Electrical Systems Check 55 Ignition System Gas Ignition 57 Commissioning 58 Pressure Testing 58 Conversion from Natural Gas to LPG 59 Guide to U...

Страница 5: ...y 9 Electric Ignition Push Button Description of the Hobs INSTALLATION Any gas installation must be carried out by a registered CORGI installer and in accordance with existing rules and regulations The relevant instructions are to be found in the second section of this manual Please ensure that once the hob is installed it is easily accessible for the engineer in the event of a breakdown Mod 21602...

Страница 6: ...eetable Burner minimum maximum diameter diameter Large rapid 160 mm 240 mm Medium semi rapid 120 mm 220 mm Small Auxiliary 80 mm 160 mm Operation Assoonasaliquidstartsboiling turndowntheflamesothatitwillbarelykeeptheliquid simmering If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to overheat Take care when fr...

Страница 7: ...eavily soiled the following products are recommended For stainless steel hobs use a proprietary stainless steel cleaner For other hobs use Hob Brite or Bar Keepers Friend Pan Supports The pan supports are dishwasher proof If washing them by hand take care when drying them as the enamelling process occasionally leaves rough edges If necessay remove stubborn stains using a paste cleaner The Burners ...

Страница 8: ...not blown u Check the burner cap and crown have been replaced correctly e g after cleaning u Check the main jet is not blocked and the burner crown is clear of food particles u Check the burner cap and crown have been replaced correctly e g after cleaning Ifafterallthesechecks yourhobstilldoesnotoperatecorrectly contactyourlocalAEGService ForceCentre Please note that it will be necessary to provid...

Страница 9: ...0 5 929 929 Your call will be routed to your local Service Force Centre For the address of your local Service Force Centre and further information about Service Force please visit the website at www serviceforce co uk CUSTOMER CARE For general enquiries concerning your AEG appliance and for further information on AEG products contact our Customer Care Department by letter or telephone at the addre...

Страница 10: ...ovable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of AEG manufacture which are not marketed by AEG European Guarantee If you should move to another country within Eu...

Страница 11: ...ge fuse IGNITION HT SPARK Spark Generator Ispra Control s BF 80066 220 240V 0 6 VA T120 Spark Gap Fixed HEAT INPUT Rear Left Burner 2 0 kW 6824 BTU HR semi rapid Front Left Burner 3 0 kW Natural Gas 10236 BTU HR rapid 2 8 kW L P G 9554 BTU HR Rear Right Burner 2 0 kW 6824 BTU HR semi rapid Front Right Burner 1 0 kW 3412 BTU HR auxiliary APPLIANCE CLASS 3 APPLIANCE CATEGORY II2H3 GAS SUPPLY Natural...

Страница 12: ...0 028 NOZZLE REFERENCE 119 Adjust 96 Adjust 70 Adjust 1 100 mm NOMINAL THERMAL POWER kW 2 8 0 65 2 0 0 45 1 0 0 33 NOMINAL FLOW RATE g h 202 43 5 144 29 72 21 5 NOZZLE REFERENCE 86 40 71 32 50 28 1 100 mm NATURAL GAS 20 mbar VALUE 37 78 MJ m3 Ws 50 7 MJ m3 TYPEOFGAS LPG GAS 28 30 37 mbar VALUE 49 92 MJ Kg Burner Dia Tap By pass 1 100mm Auxiliary 28 Semi rapid 32 Rapid 40 Aerationadjustmentnone ...

Страница 13: ...a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before ma...

Страница 14: ...led by qualified personnel to the relevant British Standards Any gas installation must be carried out by a registered CORGI installer The manufacturer will not accept liability should the above instructions or any of the other safety instructions incorporated in this book be ignored 700 mm 400 mm 100 mm 400 mm 50 mm 55 mm 50 mm 650 mm 400 mm 400 mm 100 mm 50 mm 50 mm 55 mm 600 mm 700 mm ...

Страница 15: ... the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to R 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough l...

Страница 16: ...Building over a cupboard or drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface It is also recommended to carry out the electrical connection to the hob as shown in diagrams 1 and 2 ...

Страница 17: ...t in order to avoid any contact with the bottom of the hob which can be heated when it is operated The recommended solution is shown in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections 30 20 min 60 a b FO1013 3 Dimensions are given in mm ...

Страница 18: ...eft in this seal in order to prevent spillage near the hob seeping into the cabinet below 1 Place the sealing gasket all around the edge of the cut out 2 Place the hob into the cut out and secure it by means of the relevant fixing clamps and screws as shown in the diagram 3 Remove the excess seal The edge of the hob forms a double seal which prevents the ingress of liquids FO0199 a Seal F ...

Страница 19: ...t of having to change the fuse a 3amp ASTA approved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live 1 Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and...

Страница 20: ... 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations The switch must not break the yellow and green earth cable at any point Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg C B L N 0 1 2 3 4 220 240 A Wiring diagram A IGNITOR SWITCH B IGNITOR UNIT ...

Страница 21: ...ctricity supply shouldnowbe satisfactory Carry out D Resistanceto Earthcheck Inlet wiring faulty Rectify any fault Isolate appliance and carry out B Insulationcheck Rectify any fault including replacing fusesasnecessary NO YES SOCKET faceview PLUG withcoverremoved EarthWire Green Yellow NeutralWire Blue FUSE E N L Brown Blue Green Yellow Green Yellow Brown Blue NO YES ...

Страница 22: ...st leads from L to N in appliance terminal block If meter reads 0 then there is a short circuit b meter set on W Ohm x 100 scale Repeat test with leads from L to E If meter reads less than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty c...

Страница 23: ...e electrode Checkbypasssimmer adjusted Light burner manually Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks i...

Страница 24: ... see diagram The b type has the adjustment screw located down the centre of th egas tap control shaft The c type has the by pass screw located to the side of the gas tap itself To adjust use a thin bladed screwdriver and turn the adjustment screw until the flame is steady and does not extinguish when the knob is turned from MIN to MAX Repeat this procedure for all burners Pressure Testing 1 Remove...

Страница 25: ...b from the electricity supply 3 Remove all pan supports burner caps rings crowns and control knobs 4 With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors TO ADJUST THE GAS RATE With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw Upon completion stick the replacement rating plate on the ...

Страница 26: ...orld s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...

Отзывы: