Safety distances of the primary sauna 

unit and the recommended location in 

the sauna room.

POWER

 OF THE HEATER

If there is sufficient insulation behind the 
wall and ceiling covering, the power of the 
heater is determined by the volume of the 
sauna room. Non-insulated walls (brick, 
glass block, glass, concrete, floor tiles, etc.) 
need a more powerful heater. Add 1.2 m³ 
to the volume of the sauna room for each 
square metre of uninsulated wall.

For example

, a 10 m³ sauna room with 

a glass door corresponds to the capacity 
 requirement of a 12 m³ sauna room. If the 
sauna room has log walls, multiply the 
 volume by 1.5. The optimal sauna room 
sizes for the sauna climate device Saunum 
Primary Set are given in Table 1 (see  pages 
10–11). The height of the sauna room is 
usu ally 2,100 to 2,300 mm.

The minimum height when installing the 
sauna climate device Saunum Primary
Set is 1,800 mm.

•  Saunum Primary Set B – A and B 50 mm 

– model with a closed stone basket.

•  Saunum Primary Set – A and B 150 mm 

– model with an open stone basket.

The device can be placed with its back­

side against the sauna room cladding 

or panels!

DIREC

TION

 FOR USE

DIREC

TION

 FOR USE

Non-combustible 
material

Содержание Primary Set

Страница 1: ...Saunum Primary Set heater with a sauna room indoor climate device INSTRUCTION FOR USE AND INSTALLATION ENG...

Страница 2: ...had to solve the problem of how to achieve an even temperature at both the head and foot levels My development work was supported by research done alongside Tallinn University of Technology in which w...

Страница 3: ...__________ Maintenance _______________________________________ Sauna room _________________________________________ Sauna room ventilation_______________________________ Power of the heater __________...

Страница 4: ...TION Saunum Primary Set 4 5 kW C10 C10 6 kW Saunum Primary Set Saunum Primary Set 9 kW C16 C20 12 kW Saunum Primary Set 3 phase 5x1 5 5x2 5 5x4 5x2 5 Saunum Primary Set B 4 5 kW C10 C10 6 kW Saunum Pr...

Страница 5: ...a climate device are switched off the heating and the fan have stopped ADJUSTING THE TEMPERATURE NB It is recommended to keep the air cir culation fan of the sauna climate device switched off during t...

Страница 6: ...heir own weight but load the stones so that they support each other Do not stack the stones on the heater Do not place objects in the vicinity of the stone area or the fan of the sauna climate device...

Страница 7: ...e desired temperature in a properly insulated sauna room Make sure that the ventilation of the sauna room is correct Reduce the speed of the sauna climate device fan THE WALL COVERING OR OTHER MATERIA...

Страница 8: ...s in the fan air vents of the sauna climate device CAUTION Before maintaining and clean ing the sauna climate device the device power supply must be disconnected from the mains and the moving parts of...

Страница 9: ...h a glass door corresponds to the capacity requirement of a 12 m sauna room If the sauna room has log walls multiply the volume by 1 5 The optimal sauna room sizes for the sauna climate device Saunum...

Страница 10: ...able for the given sauna room The recommended sauna room volume is given in Table 1 see pages 10 11 The supply voltage is suitable for the sauna climate device At the installation site of the sauna cl...

Страница 11: ...ntsrequiredforope ration that are not part of the primary compo sition automatics power supply cables and stones 4 5 kW and 6 kW A D C E B A Flue cap B Telescopic flue C Stone basket D Front panel E S...

Страница 12: ...ing and fas ten with a mounting suitable for the base material It can be attached to the wall and or the ceiling Centre the heater under the cap and adjust the feet so that the device is level Careful...

Страница 13: ...TONES on page 14 Remove the switch button Push the front panel up as far as it will go Pull from under the panel edge outwards Remove the panel by holding it slightly tilted and pulling it downwards P...

Страница 14: ...n be up to 500 mm The connection cable must be a rubber insulated type H07RN F cable or equivalent To access the device electrical connections it is necessary to open the bot tom panel To open the pan...

Страница 15: ...se use earthed cables of at least 1 5 mm2 to power the fan The power cable must enter the housing of the sauna climate device so that the water does not flow along the cable into the electrical connec...

Страница 16: ...reserves the right to decide whether to replace the defective product component or to replace the device with a new one The replaced defective product components remain the property of Saunum Warrant...

Страница 17: ..._________________________________________________________ Checked by _____________________________________________________________ Date signature ______________________________________________________...

Страница 18: ...f Europe provided that the installation has been performed in accordance with the installation instructions issued by the device manufacturer and the instructions EN 60 204 1 Safety of the machinery E...

Отзывы: