BEFORE THE
INSTALLATION
The installation of the sauna climate device
must be performed by a qualified electri-
cian. The connection of the device must be
performed in a stable location with a cable
that meets the temperature conditions.
Protective earthing (PE) must be connected
to the connection terminal of the device,
with the cross-sectional area of the cable
being at least 2.5 mm2. The device must be
powered from the control device’s supply
circuit, which is protected by over-current
fuses. The required over-current fuses sizes
and the connection cables dimensions are
given in Table 1 (see pages 10–11).
All the certified sauna control devices with
the operating capacity corresponding to
the capacity of the Saunum Primary Set
model used in accordance with Table 1 (see
pages 10–11) may be used to control the
sauna climate control device.
Before starting the installation work,
read the installation instructions and
observe the following:
• The power and type of the heater are
suitable for the given sauna room.
The recommended sauna room
volume is given in Table 1 (see pages
10–11).
• The supply voltage is suitable for the
sauna climate device.
• At the installation site of the sauna
climate device, the minimum safety
distances given in Table 1 (see pages
10–11), measured from the heater
housing, are guaranteed.
• The dimensions of the device are
shown in Figures 1 and 2 (see pages
23).
• It must also be ensured that the
upper edge of the fan outlet of the
sauna climate device is lower than
the lower edge of the bench.
• There must be no obstructions
in front of the air outlet from the
device, the exhaust air flow must be
able to flow freely across the sauna
room.
• The device works most efficiently
when its flue cap is installed against
the ceiling of the sauna room and
the exhaust air is blown under the
bench.
• Safety distances must be complied
with unconditionally, as failure to do
so may result in a fire hazard. Only
one sauna climate device may be
installed in the sauna room.
Saunum Primary Set
4.5 kW and 6 kW
Saunum Primary Set
9 kW and 12 kW
450 mm
1800–2400 mm
815 mm
Figure 1
Figure 2
227 mm
310 mm
465 mm
1045 mm
450 mm
1800–2400 mm
227 mm
310 mm
465 mm
DIMENSIONS
INST
ALLING