![Saunier Duval Semia Condens F24 E Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/saunier-duval/semia-condens-f24-e/semia-condens-f24-e_instructions-for-use-installation-and-servicing_1202896045.webp)
Installation and servicing instructions strictly reserved for qualifi
ed gas installers
43
16 Technical data
Boiler type B22-C12-C32-C42-C52-C62-C82
Description
Unit
SEMIA CONDENS
F24 E
SEMIA CONDENS
F30 E
Gas category
ll
2H3+
ll
2H3+
Heating output at 80°C/60°C (Hi)
kW
18.1 - 24.5
11.1 - 28.6
Efficiency calculated on net calorific value
at 80/60°C
%
94.9 - 95.8
95.2 - 97.1
Heating output at 50°C/30°C (P)
kW
19.2 - 26.2
15.9 - 30.6
Efficiency calculated on net calorific value
at 50/30°C
%
101.1 - 102.2
100.5 - 103.8
Heat input (Hs) (heating)
kW
21.08 - 28.4
17.76 - 32.74
Heat input (Hs) (DHW)
kW
11.65 - 28.4
13.3 - 32.74
Maximum hot water temperature
°C
80
80
Heating
Heating temperature range (standard)
C°
30 - 80
30 - 80
Heating temperature range (low temp.)
C°
25 - 45
25 - 45
Expansion vessel, useful capacity
l
8
8
Expansion tank initial pressure
bar
1
1
Safety valve, maximum service pressure
(PMS)
bar
3
3
Domestic hot water
Hot water temperature range
°C
30-70
30-70
Specific flow rate (D) (ΔT 25°C)
l/min
14.0
16.4
Specific flow rate (D) (ΔT 30°C)
l/min
11.7
13.7
Specific flow rate (D) (ΔT 35°C)
l/min
10.0
11.7
Threshold flow rate
l/min
3
3
Maximum supply pressure
bar
6
6
Minimum operating pressure
bar
0.8
0.8
Combustion
Product outlet flow rate
g/s
15.9
16.4
Product outlet temperature
°C
85
70
Values of product outlet (measured on nominal heating output with G20 reference gas):
CO
ppm 38.0
54.8
CO2
%
6.40
7.20
NOx balance
mg/
kWh
163.1
122.0
Содержание Semia Condens F24 E
Страница 2: ......
Страница 23: ...Installation and servicing instructions strictly reserved for quali ed gas installers 21 1041_R00...
Страница 48: ......
Страница 49: ......
Страница 50: ...982790002 000...