14
The appliance is room sealed, so when
it is installed in a room or space, a
permanent air vent is not required.
Do not install the appliance above
another appliance that could damage
it (for example, above a cooker that
might emit steam or grease) or in a
room, which has a lot of dust in the
atmosphere which is corrosive.
4 Safety instructions and
regulations
This appliance is tested and certifi cated
for safety and performance. It is, therefore,
important that no alteration is made to the
appliance, without permission, in writing,
from Saunier Duval.
Any alteration not approved by Saunier
Duval, could invalidate the certifi cation,
appliance warranty and may also
infringe the current issue of the statutory
requirements.
4.1 Safety
instructions
If the gas pressure at the input of the
appliance is outside the range specifi ed,
you shall not start the appliance. If the
cause of the problem cannot be found
nor solved, please contact the Gas Utility
company.
Warning! Incorrect installation can cause
electric shock or appliance damage.
When making the connections, locate
the sealing washers properly so as to
avoid any gas or water leakage.
Never use a wire brush or stiff-bristle
scrubbing brush to clean the heat
exchanger as this could damage the
appliance.
Under no circumstances must the User
interfere with or adjust sealed parts.
Under Section 6 of The Health and
Safety at Work Act 1974, we are required
•
•
-
-
-
to provide information on substances
hazardous to health.
The adhesives and sealants used in this
appliance are cured and give no known
hazard in this state.
In the event of the appliance overheating
the safety devices will cause a safety
shutdown. If this happens, call your
installation/servicing company.
Warning! This appliance must be
earthed. This appliance must be wired in
accordance with these instructions. Any
fault arising from incorrect wiring cannot
be put right under the terms of the Saunier
Duval guarantee.
The following safety instructions must
be imperatively followed during the
maintenance and the replacement of
spare parts.
Stop the appliance (see chapter “Turn
the boiler off” in the “Instructions for
use” section,
in this manual
).
Deactivate the appliance from the
mains power supply with the socket or
the double-pole switch (with a minimum
gap of 3mm for both poles).
Turn off the gas control valve.
Close the shut off valves located on the
connection sockets.
Drain the appliance when you want
to change the hydraulic parts of the
appliance.
Let the appliance cool down before
undertaking any maintenance
operation.
Protect all the electrical components
from water when you achieve any
operations.
Use only new O-rings and gaskets.
•
•
•
•
•
•
•
•