RX-2K • RX-4K
SATEL
flashing red – transmission has been received from keyfob with low battery.
tamper switch.
antenna.
MODE1, MODE2, MODE3 and MODE4 pins. To be used for setting the operating mode
of relay outputs. The digit stands for the number of the relay output.
PRG1, PRG2, PRG3 and PRG4 buttons. Allow you to enroll keyfobs and define the cut-
off time of relay outputs. The digit stands for the number of the control channel / relay
output. The PRG2 [RX-2K] / PRG4 [RX-4K] button can be used to start communication
with the DLOAD10 program. The PRG1 button can be used to restore the factory default
settings.
Note:
The RX-2K controller has no MODE3 / MODE4 pins and PRG3 / PRG4 buttons.
Terminals
TMP
- NC type tamper output (opening the tamper switch opens the output). You can
connect the TMP output to the appropriately programmed output of the alarm
control panel.
AR
- input supervising the armed status in the alarm system. The input is activated
after applying the common ground. Connect the AR input to the control panel
OC type output programmed as “Armed status”.
AL
- input supervising the alarm status in the alarm system. The input is activated
after applying the common ground. Connect the AL input to the control panel
OC type output indicating the alarm to be cleared.
LV
- output indicating low battery in the keyfob. The output will be turned on after
receiving a transmission from the keyfob with low battery. The output will be
turned off after receiving a transmission from the keyfob whose battery is OK.
OC type output (shorted to common ground when active). You can connect
e.g. a LED to the LV output, or you can connect the output to an appropriately
programmed zone of the alarm control panel.
SS
- output indicating arming / disarming / alarm clearing in the alarm system. The
indication will be triggered if the AR and/or AL input status is changed within
4 seconds of receiving a transmission from the keyfob. The indication is
provided in the form of pulses of 0.16 second duration:
1 pulse – arming,
2 pulses – disarming,
4 pulses – disarming and/or alarm clearing.
OC type output (shorted to common ground when active). You can connect
e.g. a siren to the SS output.
+12V
- power input (9...16 V DC).
COM
-
common
ground.
C1...C4
- relay output common contact.
NC1...NC4
- relay output normally closed contact.
NO1...NO4
- relay output normally open contact.
Note:
The RX-2K controller has no terminals of relay outputs 3 and 4.