Fig. 16. Connection of printer by means of DIN 5-pin plug (solder side view). Shown on the
left is RJ plug to be connected into the control panel mainboard socket.
6. Numeration of zones and outputs in the system
Numbers are automatically assigned to the zones and outputs:
•
the hardwired zones and outputs on the control panel board are numbered from 1 to 8.
•
numbers of the wireless zones and outputs supported by the INTEGRA 128-WRL control
panel mainboard are set during the procedure of adding wireless devices – free and
available numbers are assigned.
Numeration of wireless devices supported by the INTEGRA 128-WRL control panel
mainboard need not be continuous. For example, if the system includes 8 wireless
zones with numbers 17-24, to which wireless devices are assigned, and the zones
25-32 are already reserved for the expander, then adding a new wireless device will
result in reservation of next 8 zones with numbers 33-40 for wireless devices.
Numbering of the expander zones will remain unchanged. The same rules apply to the
wireless outputs.
•
the numbers of keypad zones are determined during the identification procedure, based on
the keypad address (see section N
UMERATION OF KEYPAD ZONES
p. 16).
•
the numbers of zones and outputs in expanders and ABAX 2 / ABAX system controllers
are determined during the expander identification procedure. The numbering is dependent
on the expansion module address in the system (zones in expansion module with a lower
address will be given lower numbers than the zones in expansion module with a higher
address).
The control panel reserves 8 zones in the system for each identified expander. The
exceptions are the INT-ADR / CA-64 ADR expander and the ABAX 2 / ABAX
controllers, for which up to 48 zones can be reserved. In case of the INT-ADR /
CA-64 ADR expander, the number of reserved zones depends on the number of
detectors with installed CA-64 ADR MOD module, which are connected to it. In case of
the ABAX 2 / ABAX system controller, the number of reserved zones depends on the
number of registered wireless devices. In both cases, the number of reserved zones is
a multiple of 8.
The DLOADX program allows you to change the numeration of zones and outputs in
expanders (“Structure” window, “Hardware” tab, “Advanced” button for the selected