Module installation and starting
7
Maximum door open time: - Time, after which the module signals an event “door is
opened for long time” to the control panel and activates audible signal, is set in this field.
A time period from 0 to 255 seconds may be set.
♦
Dependent on door (1) (or Dependent on door (2)): - The field, where you can select
(from the list) which door must be closed to activate the lock. Door status monitoring is
carried out via input IN at the partition keypad or an input type 57 (technical input – door
monitoring). This function makes it possible to create a “sluice” type passageway.
♦
Users – When you click with the mouse to this field, a new dialog window opens (see Figure
4) which is used for setting the list of users (administrators and ordinary users), who may
use this partition keypad. Mark the user name to render accessible the partition keypad for
him.
♦
Additional features (marking the option will
make accessible the following functions):
FIRE Alarm – When you press the key
designated with
9
, you will activate a fire
alarm.
AUX Alarm - When you press the key
designated with digit “0”, you will activate
an auxiliary alarm.
PANIC Alarm - When you press the key
designated with #, you will activate an
attack alarm.
Silent (PANIC alarm) – When this option is
activated, the PANIC alarm started with a
partition keypad does not trigger an audible
alarm, but a message is transmitted to the
monitoring station only, and the input type
12 (“silent alarm”) is activated.
Figure 4
Changing access code – When this option is marked, the user code change function is
accessible.
Quick arming – Arming by pressing the keys 0 and # in sequence.
Control “BI” output – This option allows the partition keypad to accept the code, for
which the user type has been determined as a “bistable output”.
Control “MONO” output – This option allows the partition keypad to accept the code, for
which the user type has been determined as a “monostable output”.
Partition bypass – entering the guard code, when the partition is armed, activates
temporary partition bypass.
Guard round control – entering the guard code (CODE # or CODE
9
) will be treated as
a completion of a guard round.
Alarm – three incorrect codes – When an erratic code is typed three times, an alarm
will be generated.
Alarm signalling (fixed time) – audible alarm for a given partition (for the total alarm
duration time).
Alarm signalling (latch) - audible alarm for a given partition until it is cleared.
Signalling entry delay – audible signalling when the entry delay is counted-down.
Auto-Arm delay countdown - the countdown of the Auto-Arm delay will be signalled
with a sound from the keypad that has been assigned to the partition.
No auto-reset after 3 tamp. - each expander automatically blocks its tamper alarm
function after three consecutive (not cleared) tamper alarms, which prevents the same