Module installation and starting  

 

ƒ

  Maximum door open time: - Time, after which the module signals an event “door is 

opened for long time” to the control panel and activates audible signal, is set in this field. 
A time period from 0 to 255 seconds may be set.  

  Dependent on door (1) (or  Dependent on door (2)):  - The field, where you can select 

(from the list) which door must be closed to activate the lock. Door status monitoring is 
carried out via input IN at the partition keypad or an input type 57 (technical input – door 
monitoring). This function makes it possible to create a “sluice” type passageway.  

 

  Users – When you click with the mouse to this field, a new dialog window opens (see Figure 

4) which is used for setting the list of users (administrators and ordinary users), who may 
use this partition keypad. Mark the user name to render accessible the partition keypad for 
him.  

  Additional features (marking the option will 

make accessible the following functions):  

ƒ

  FIRE Alarm – When you press the key 

designated with 

9

, you will activate a fire 

alarm.   

ƒ

  AUX Alarm  - When you press the key 

designated with digit “0”, you will activate 
an auxiliary alarm.  

ƒ

  PANIC  Alarm  - When you press the key 

designated with #, you will activate an 
attack alarm.  

ƒ

  Silent (PANIC alarm) – When this option is 

activated, the PANIC alarm started with a 
partition keypad does not trigger an audible 
alarm, but a message is transmitted to the 
monitoring station only, and the input type 
12 (“silent alarm”) is activated.  

Figure 4

 

ƒ

  Changing access code – When this option is marked, the user code change function is 

accessible.  

ƒ

  Quick arming – Arming by pressing the keys 0 and # in sequence.  

ƒ

  Control “BI” output – This option allows the partition keypad to accept the code, for 

which the user type has been determined as a “bistable output”.   

ƒ

  Control “MONO” output – This option allows the partition keypad to accept the code, for 

which the user type has been determined as a “monostable output”.   

ƒ

  Partition bypass – entering the guard code, when the partition is armed, activates 

temporary partition bypass.  

ƒ

  Guard round control – entering the guard code (CODE # or CODE 

9

) will be treated as 

a completion of a guard round.  

ƒ

  Alarm – three incorrect codes – When an erratic code is typed three times, an alarm 

will be generated.  

ƒ

  Alarm signalling (fixed time) – audible alarm for a given partition (for the total alarm 

duration time).  

ƒ

  Alarm signalling (latch) - audible alarm for a given partition until it is cleared. 

ƒ

  Signalling entry delay – audible signalling when the entry delay is counted-down.  

ƒ

  Auto-Arm delay countdown - the countdown of the Auto-Arm delay will be signalled 

with a sound from the keypad that has been assigned to the partition. 

ƒ

  No auto-reset after 3 tamp. - each expander automatically blocks its tamper alarm 

function after three consecutive (not cleared) tamper alarms, which prevents the same 

Содержание CA-64 S

Страница 1: ...ms that the partition assigned to this partition keypad is armed The LED blinks when the delay time is counted down TROUBLE yellow the LED blinks when technical problem has been detected in the system Check LCD keypad for a kind of trouble Indication of this LED relates to the entire system not only the partition operated with this partition keypad When this partition is armed the LED goes off and...

Страница 2: ...ause disarming and operation of the relay only if the partition isn t temporary bypassed and the user has the right to disarm and use this keypad There is a possibility to control various equipment with the control panel for example switching off the lighting starting air conditioning etc The installer should inform the user which equipment may be operated by means of the given keypad Control func...

Страница 3: ... user who enters his code now or end of code validity period Four short beeps and one long beep acceptance of execution of function selected code change done confirmation of a guard round Five short beeps dependent door open the relay has not been activated In order to activate the relay close the dependent door and enter code again Flashing of key lighting may be arranged instead of audible signa...

Страница 4: ...ou start to wire the module to the existing alarm system 1 Remove the plastic module casing by pressing the clips which fix the casing bottom 2 Fix the bottom of plastic casing to the wall The connecting leads should be passed through the rectangular opening in this part of casing 3 Connect the leads of first or second expander bus to the following terminals DTA CLK and COM first bus CK1 DT1 COM s...

Страница 5: ...tion process the control panel saves into memory the special number 16 bits which is used for checking the presence of the module in the system Replacement of the module with another one even if the same address is set without carrying out the identification process again causes alarm module tamper verification error 4 Program the partition keypad functions and define users authorised to use this ...

Страница 6: ...F if door open The relay is active until the door is open input IN is disconnected from ground but no longer than for the Relay ON time Fixed ON time OFF if door closed The relay is active for the duration of door opening input IN disconnected from ground and it is de activated when the door is closed input IN is connected to ground again but the relay is active no longer than the Lock ON time Rel...

Страница 7: ...tition keypad does not trigger an audible alarm but a message is transmitted to the monitoring station only and the input type 12 silent alarm is activated Figure 4 Changing access code When this option is marked the user code change function is accessible Quick arming Arming by pressing the keys 0 and in sequence Control BI output This option allows the partition keypad to accept the code for whi...

Страница 8: ...fter pressing any key à Zone violation key backlit is switched on also when the zone with the number entered in the field next to the option name has been violated à Entry delay part key backlit is also switched on when the entry delay counting down is started in the partition with the number entered in the field next to the option name NOTE Automatic keypad backlit is active for approximately 40 ...

Отзывы: