Partition keypad 

CA-64 S   SATEL 

 

>

 

CODE 

9

 

control of relay located at the module board (for example, opening of the 
electromagnetic door lock).   

There is a possibility to program the partition (service setting) to be opened or closed after 
entering two different codes. In this case, after CODE is entered and key # is pressed, the 
LEDs ARMED and TROUBLE (green and yellow), start to blink, and the control panel waits for 
entering the second code. The second CODE may be typed either at the same keypad or at 
another one (also, at LCD keypad), which is assigned for this partition. Pressing the key # 
after the second code arms and disarms in the partition.  

The possibility to change the code by the user is an additional function of the keypad (service 
setting).  

The user, who wants to start functions mentioned above, must be authorised to use this keypad 
(authorisation is given by alarm system administrator or installer). Additionally, in order to use 
the first of those functions, the user must have access to the partition in question and adequate 
authorisation given by the system administrator or, by the person, who entered the user’s code 
to the system.  

For example: The user, who is authorised to operate a partition keypad, but has not access to 
a particular partition or has access but no right to disarm the partition, can operate the relay of 
this keypad by entering the CODE and pressing key 

9

 only when the partition is disarmed.  

When this partition is disarmed and the keypad controls the relay, entering the CODE and 
pressing key 

9

 will cause disarming and operation of the relay only if the partition isn’t 

temporary bypassed, and the user has the right to disarm and use this keypad.  

There is a possibility to control various equipment with the control panel (for example, switching 
off the lighting, starting air-conditioning, etc.). The installer should inform the user, which 
equipment may be operated by means of the given keypad.  
Control functions are executed by typing the special CODE into the keypad (for which the user 
type has been selected as “monostable output” or “bistable output”) and pressing the key #.  

When the erratic code is typed three times, the alarm may be activated (service setting). 

Code change by the user is carried out as follows:  

ƒ

  Keep pressed for a longer time (approximately 3 seconds) the key with digit 1 (LEDs  

ALARM and ARMED – red and green – start to blink alternately). 

ƒ

  Type old CODE and press # (LEDs: ALARM and TROUBLE – red and yellow - start to 

blink alternately). 

ƒ

  Type new CODE and press # (LEDs stop blinking and the module generates 

confirmation signal of the function executed).  

The control panel may refuse changing the code - it is signalled with two long sounds. 
Information on the refusal of code changing is available in the "User’s Manual for CA-64" 
(

Æ

Operation of Control Panel CA-64, 

Æ

Partition Keypad). 

 

The system installer may render accessible other functions from the partition keypad, for 
which code entering is not required:  

>

 

0 # 

quick partition arming (function called by pressing two keys: 0 and # in 

sequence).  

and functions of triggering special alarms:  

9

 # 

panic alarm,  

9

 0 

auxiliary alarm (for example, calling for medical aid),  

9

 

9

 

fire alarm.  

The last three functions are started by longer keeping depressed (for approximately 3 seconds) 
the key described above. 

Содержание CA-64 S

Страница 1: ...ms that the partition assigned to this partition keypad is armed The LED blinks when the delay time is counted down TROUBLE yellow the LED blinks when technical problem has been detected in the system Check LCD keypad for a kind of trouble Indication of this LED relates to the entire system not only the partition operated with this partition keypad When this partition is armed the LED goes off and...

Страница 2: ...ause disarming and operation of the relay only if the partition isn t temporary bypassed and the user has the right to disarm and use this keypad There is a possibility to control various equipment with the control panel for example switching off the lighting starting air conditioning etc The installer should inform the user which equipment may be operated by means of the given keypad Control func...

Страница 3: ... user who enters his code now or end of code validity period Four short beeps and one long beep acceptance of execution of function selected code change done confirmation of a guard round Five short beeps dependent door open the relay has not been activated In order to activate the relay close the dependent door and enter code again Flashing of key lighting may be arranged instead of audible signa...

Страница 4: ...ou start to wire the module to the existing alarm system 1 Remove the plastic module casing by pressing the clips which fix the casing bottom 2 Fix the bottom of plastic casing to the wall The connecting leads should be passed through the rectangular opening in this part of casing 3 Connect the leads of first or second expander bus to the following terminals DTA CLK and COM first bus CK1 DT1 COM s...

Страница 5: ...tion process the control panel saves into memory the special number 16 bits which is used for checking the presence of the module in the system Replacement of the module with another one even if the same address is set without carrying out the identification process again causes alarm module tamper verification error 4 Program the partition keypad functions and define users authorised to use this ...

Страница 6: ...F if door open The relay is active until the door is open input IN is disconnected from ground but no longer than for the Relay ON time Fixed ON time OFF if door closed The relay is active for the duration of door opening input IN disconnected from ground and it is de activated when the door is closed input IN is connected to ground again but the relay is active no longer than the Lock ON time Rel...

Страница 7: ...tition keypad does not trigger an audible alarm but a message is transmitted to the monitoring station only and the input type 12 silent alarm is activated Figure 4 Changing access code When this option is marked the user code change function is accessible Quick arming Arming by pressing the keys 0 and in sequence Control BI output This option allows the partition keypad to accept the code for whi...

Страница 8: ...fter pressing any key à Zone violation key backlit is switched on also when the zone with the number entered in the field next to the option name has been violated à Entry delay part key backlit is also switched on when the entry delay counting down is started in the partition with the number entered in the field next to the option name NOTE Automatic keypad backlit is active for approximately 40 ...

Отзывы: