Module installation and starting  

 

addressing is optional. It is recommended to address the expanders and modules 
connected to one bus in sequence, starting from 0. This will allow avoiding problems when 
extending the system.  

5.  Connect the module power supply to the te12V. Power supply for a  keypad may be 

provided from a source other than the control panel main board. It may come from a buffer 
power pack or another expander with a power pack. Detailed information on wiring are given 
in the manual for the CA-64 control panel titled “System description and installation”.  

6.  Connect the leads of the door status monitoring sensor to IN and COM terminals.  
7.  If the partition keypad is to play a role of a code lock, connect the door electromagnetic lock 

leads (or leads for another device) to terminals NO.  

8.  Fix the partition keypad module to the wall by clasping the plastic casing.  

STARTING THE MODULE 

 

1.  Switch on the alarm system power supply.  

2.  Start the communication between the control panel and the computer by calling the function 

Downloading”.  

3.  Call the function “Identification of expanders” from the LCD keypad (

Á

Service mode; 

Á

Structure; 

Á

Hardware). after identification, the value of all settings is zero or “None”, and 

options are switched off. Since the pressing of keys is not confirmed, it seems like the 
module does not respond to code entering. 

NOTE:  

During the identification process, the control panel saves into memory the special 
number (16 bits), which is used for checking the presence of the module in the 
system. Replacement of the module with another one (even if the same address 
is set) without carrying out the identification process again causes alarm (module 
tamper – verification error).  

4.  Program the partition keypad functions and define users authorised to use this partition 

keypad by means of DLOAD64 program.  

5.  Exit the service mode by storing the data in the FLASH memory.  

6.  Terminate the communication with computer and save the data with system settings in a 

separate file.  

PROGRAMMING OF PARTITION KEYPAD SETTINGS 

 

The dialogue window shown in Figure 3 is used for programming the partition keypad settings in 
the DLOAD64 program. Programming is carried out by typing data at the computer keyboard, 
selecting the items from the list or marking the options by means of computer mouse.  

  Name: 

- the field, where an individual name (16 characters) is assigned to the module.  

  Partition: - the field, where the partition keypad is assigned to the partition (selected from the 

list).  

  Lock feature: 

- When this option is marked, the electromagnetic lock (or another 

equipment, which requires access control) may be operated with a partition keypad. This 
function is rendered accessible for each user, who has been marked in the option “Users”. 
The lock is operated by means of relay contacts NO (normally closed; normally open). The 
normal (basic) status of a relay contact depends on setting of the “Relay” option. The 
description of the function relates to a typical application.  

 

Содержание CA-64 S

Страница 1: ...ms that the partition assigned to this partition keypad is armed The LED blinks when the delay time is counted down TROUBLE yellow the LED blinks when technical problem has been detected in the system Check LCD keypad for a kind of trouble Indication of this LED relates to the entire system not only the partition operated with this partition keypad When this partition is armed the LED goes off and...

Страница 2: ...ause disarming and operation of the relay only if the partition isn t temporary bypassed and the user has the right to disarm and use this keypad There is a possibility to control various equipment with the control panel for example switching off the lighting starting air conditioning etc The installer should inform the user which equipment may be operated by means of the given keypad Control func...

Страница 3: ... user who enters his code now or end of code validity period Four short beeps and one long beep acceptance of execution of function selected code change done confirmation of a guard round Five short beeps dependent door open the relay has not been activated In order to activate the relay close the dependent door and enter code again Flashing of key lighting may be arranged instead of audible signa...

Страница 4: ...ou start to wire the module to the existing alarm system 1 Remove the plastic module casing by pressing the clips which fix the casing bottom 2 Fix the bottom of plastic casing to the wall The connecting leads should be passed through the rectangular opening in this part of casing 3 Connect the leads of first or second expander bus to the following terminals DTA CLK and COM first bus CK1 DT1 COM s...

Страница 5: ...tion process the control panel saves into memory the special number 16 bits which is used for checking the presence of the module in the system Replacement of the module with another one even if the same address is set without carrying out the identification process again causes alarm module tamper verification error 4 Program the partition keypad functions and define users authorised to use this ...

Страница 6: ...F if door open The relay is active until the door is open input IN is disconnected from ground but no longer than for the Relay ON time Fixed ON time OFF if door closed The relay is active for the duration of door opening input IN disconnected from ground and it is de activated when the door is closed input IN is connected to ground again but the relay is active no longer than the Lock ON time Rel...

Страница 7: ...tition keypad does not trigger an audible alarm but a message is transmitted to the monitoring station only and the input type 12 silent alarm is activated Figure 4 Changing access code When this option is marked the user code change function is accessible Quick arming Arming by pressing the keys 0 and in sequence Control BI output This option allows the partition keypad to accept the code for whi...

Страница 8: ...fter pressing any key à Zone violation key backlit is switched on also when the zone with the number entered in the field next to the option name has been violated à Entry delay part key backlit is also switched on when the entry delay counting down is started in the partition with the number entered in the field next to the option name NOTE Automatic keypad backlit is active for approximately 40 ...

Отзывы: