Module installation and starting
5
addressing is optional. It is recommended to address the expanders and modules
connected to one bus in sequence, starting from 0. This will allow avoiding problems when
extending the system.
5. Connect the module power supply to the te12V. Power supply for a keypad may be
provided from a source other than the control panel main board. It may come from a buffer
power pack or another expander with a power pack. Detailed information on wiring are given
in the manual for the CA-64 control panel titled “System description and installation”.
6. Connect the leads of the door status monitoring sensor to IN and COM terminals.
7. If the partition keypad is to play a role of a code lock, connect the door electromagnetic lock
leads (or leads for another device) to terminals NO.
8. Fix the partition keypad module to the wall by clasping the plastic casing.
STARTING THE MODULE
1. Switch on the alarm system power supply.
2. Start the communication between the control panel and the computer by calling the function
“Downloading”.
3. Call the function “Identification of expanders” from the LCD keypad (
Á
Service mode;
Á
Structure;
Á
Hardware). after identification, the value of all settings is zero or “None”, and
options are switched off. Since the pressing of keys is not confirmed, it seems like the
module does not respond to code entering.
NOTE:
During the identification process, the control panel saves into memory the special
number (16 bits), which is used for checking the presence of the module in the
system. Replacement of the module with another one (even if the same address
is set) without carrying out the identification process again causes alarm (module
tamper – verification error).
4. Program the partition keypad functions and define users authorised to use this partition
keypad by means of DLOAD64 program.
5. Exit the service mode by storing the data in the FLASH memory.
6. Terminate the communication with computer and save the data with system settings in a
separate file.
PROGRAMMING OF PARTITION KEYPAD SETTINGS
The dialogue window shown in Figure 3 is used for programming the partition keypad settings in
the DLOAD64 program. Programming is carried out by typing data at the computer keyboard,
selecting the items from the list or marking the options by means of computer mouse.
♦
Name:
- the field, where an individual name (16 characters) is assigned to the module.
♦
Partition: - the field, where the partition keypad is assigned to the partition (selected from the
list).
♦
Lock feature:
- When this option is marked, the electromagnetic lock (or another
equipment, which requires access control) may be operated with a partition keypad. This
function is rendered accessible for each user, who has been marked in the option “Users”.
The lock is operated by means of relay contacts NO (normally closed; normally open). The
normal (basic) status of a relay contact depends on setting of the “Relay” option. The
description of the function relates to a typical application.