Partition keypad 

CA-64 S   SATEL 

 

Figure 3 

LOCK  

ƒ

  ON if partition armed - When this option is marked, the relay operates in a bistable way 

(active when the partition is armed and normal when it is disarmed).  

NOTE:  

When the relay operates in this mode, it changes the status automatically, if 
the partition has been disarmed from this partition keypad. However, if the 
partition has been disarmed from another keypad, the relay changes its status 
after CODE is entered and the key 

9

 is pressed at its partition keypad.  

ƒ

  Fixed ON time – This option sets the operation mode, in which the relay works in a 

monostable way. After the user has called the door opening function (CODE 

9

) the relay 

will be activated for the time set in field the “Relay ON time:”, and then switches to its 
normal status. Activation time period may be from 1 up to 255 seconds.  

ƒ

  Fixed ON time – OFF if door open – The relay is active until the door is open (input IN 

is disconnected from ground), but no longer than for the “Relay ON time”.  

ƒ

  Fixed ON time – OFF if door closed - The relay is active for the duration of door 

opening (input IN disconnected from ground), and it is de-activated when the door is 
closed (input IN is connected to ground again), but the relay is active no longer than the 
“Lock ON time”.   

ƒ

  Relay – This option sets a way of relay contacts operation:  

à

  NO - normally contacts NO are open, they close when the relay is activated.  

à

  NC - normally contacts NO are closed, they open when the relay is activated.  

ƒ

  Authorization control – opening of the door without using a card or chip (e.g. with a 

key) will generate an „Unauthorized door opening” event, and may also be signaled on 
the 93 (Unauthorized access) type output. 

ƒ

  Alarm on unauth. access – unauthorized opening of a door when the partition to which 

the module is assigned is in the armed mode will trigger alarm.  Additionally the alarm 
may be signaled at the output of 94 type (Alarm – unauthorized access). 

Содержание CA-64 S

Страница 1: ...ms that the partition assigned to this partition keypad is armed The LED blinks when the delay time is counted down TROUBLE yellow the LED blinks when technical problem has been detected in the system Check LCD keypad for a kind of trouble Indication of this LED relates to the entire system not only the partition operated with this partition keypad When this partition is armed the LED goes off and...

Страница 2: ...ause disarming and operation of the relay only if the partition isn t temporary bypassed and the user has the right to disarm and use this keypad There is a possibility to control various equipment with the control panel for example switching off the lighting starting air conditioning etc The installer should inform the user which equipment may be operated by means of the given keypad Control func...

Страница 3: ... user who enters his code now or end of code validity period Four short beeps and one long beep acceptance of execution of function selected code change done confirmation of a guard round Five short beeps dependent door open the relay has not been activated In order to activate the relay close the dependent door and enter code again Flashing of key lighting may be arranged instead of audible signa...

Страница 4: ...ou start to wire the module to the existing alarm system 1 Remove the plastic module casing by pressing the clips which fix the casing bottom 2 Fix the bottom of plastic casing to the wall The connecting leads should be passed through the rectangular opening in this part of casing 3 Connect the leads of first or second expander bus to the following terminals DTA CLK and COM first bus CK1 DT1 COM s...

Страница 5: ...tion process the control panel saves into memory the special number 16 bits which is used for checking the presence of the module in the system Replacement of the module with another one even if the same address is set without carrying out the identification process again causes alarm module tamper verification error 4 Program the partition keypad functions and define users authorised to use this ...

Страница 6: ...F if door open The relay is active until the door is open input IN is disconnected from ground but no longer than for the Relay ON time Fixed ON time OFF if door closed The relay is active for the duration of door opening input IN disconnected from ground and it is de activated when the door is closed input IN is connected to ground again but the relay is active no longer than the Lock ON time Rel...

Страница 7: ...tition keypad does not trigger an audible alarm but a message is transmitted to the monitoring station only and the input type 12 silent alarm is activated Figure 4 Changing access code When this option is marked the user code change function is accessible Quick arming Arming by pressing the keys 0 and in sequence Control BI output This option allows the partition keypad to accept the code for whi...

Страница 8: ...fter pressing any key à Zone violation key backlit is switched on also when the zone with the number entered in the field next to the option name has been violated à Entry delay part key backlit is also switched on when the entry delay counting down is started in the partition with the number entered in the field next to the option name NOTE Automatic keypad backlit is active for approximately 40 ...

Отзывы: