The
main
features
of
the
EQUALIS
S
flow
computer
are
the
following:
Graphic
display:
Any
information
necessary
required
to
use
the
EQUALIS
S
is
displayed
on
a
single
screen,
in
a
way
that
is
user
‐
friendly
and
interactive.
Dust
and
water
resistant:
EQUALIS
has
been
developed
and
manufactured
in
such
a
way
as
to
make
it
resistant
to
the
risks
of
everyday
use
and
the
elements.
Adjustable
meter
curve:
The
EQUALIS
has
a
parameter
used
to
correct
the
curve
by
reducing
the
counter
to
0
‰
measurement
error
at
operation
flow
rate.
It
also
provides
the
possibility
to
linearize
the
curve
by
using
an
error
correction
parameter
in
6
sectors.
Hard
disk
memory:
The
transactions
as
well
as
the
system’s
configuration
and
calibration
parameters
are
backed
‐
up
in
a
secure
database.
The
capacity
of
this
memory
allows
to
save
up
to
50
000
transactions.
EQUALIS
S
also
allows
consulting
and
reprinting
transactions
which
are
stored
in
this
database.
The
metrological
data
featured
on
this
ticket
is
recognised
by
legal
metrology
authorities.
Dual
channels
for
pulses:
EQUALIS
S
may
be
connected
to
1
or
2
pulse
transmitters.
Where
2
pulse
transmitters
are
connected,
EQUALIS
S
displays
the
total
volume
from
these
two
2
counters.
Systematically
for
this
(these)
transmitter(s),
the
EQUALIS
S
counts,
stores
and
compares
the
two
pulse
channels
for
each
transmitter
with
a
phase
shift
of
90°.
If
any
disparity
is
detected
between
their
2
respective
pulse
trains,
the
delivery
is
stopped,
thus
also
preventing
loss
of
product
due
to
a
defective
transmitter.
For
complete
information
about
Equalis
S
operation
please
refer
to
following
technical
manual
:
Reference
Technical
manual
U517478
Equalis
S
Installation
manual
U517504
Equalis
S
Programming
manual
C.
Mechanical
register
The
mechanical
register
is
a
mechanical
indicator.
It
display
the
measured
volume
at
operating
conditions.
The
resettable
volume
is
displayed
with
5
digits
and
the
non
‐
resettable
volume
is
displayed
with
8
digits.
For
complete
information
about
mechanical
register
operation
please
refer
to
following
technical
manual
:
Reference
Technical
manual
U508218
VR7887
Description,
installation,
operation,
servicing
Содержание ZCM17
Страница 1: ...02 2018 Edition 1 19 U518156 en REV0 MASTER METER Description Operation Maintenance ...
Страница 12: ...02 2018 Edition 12 19 U518156 en REV0 B Adjustment Procedure with EQUALIS S ...
Страница 13: ...02 2018 Edition 13 19 U518156 en REV0 ...
Страница 14: ...02 2018 Edition 14 19 U518156 en REV0 ...
Страница 15: ...02 2018 Edition 15 19 U518156 en REV0 ...