SATAM ZCM17 Скачать руководство пользователя страница 7

 

02/2018

 

Edition

 

7/19

 

U518156

en

REV0

 

For

 

complete

 

information

 

about

 

ZC17

 

operation

 

please

 

refer

 

to

 

following

 

technical

 

manuals

 

:

  

Reference

 

Technical

 

manual

 

U508131

 

Description,

 

installation,

 

operation,

 

servicing

  

for

 

ZC17

24

 

and

 

ZC17

48

 

U508334

 

Description,

 

installation,

 

operation,

 

servicing

  

for

 

ZC17

80;

 

ZC17

150,

 

ZC17

250

 

and

 

ZC17

330

 

 

B.

 

Electronic

 

register

 

EQUALIS

 

S

 

 

The

 

EQUALIS

 

S

 

Field

 

Batch

 

Controller

 

depot

 

version

 

is

 

an

 

intelligent

 

electronic

 

calculator/indicator,

 

controlled

 

by

 

several

 

embedded

 

microprocessors,

 

designed

 

for

 

efficient

 

management

 

of

 

fluid

 

measurement.

 

It

 

carries

 

out

 

the

 

calculation,

 

display

 

and

 

management

 

functions,

 

essential

 

to

 

product

 

loading

 

or

 

unloading.

 

EQUALIS

 

is

 

designed

 

to

 

be

 

used

 

in

 

an

 

explosive

 

atmosphere,

 

with

 

different

 

protection

 

modes,

 

in

 

accordance

 

with

 

directive

 

ATEX

 

94/9/CE.

 

It

 

is

 

designed

 

to

 

ensure

 

the

 

data

 

backup

 

of

 

the

 

current

 

deliveries

 

in

 

the

 

event

 

of

 

a

 

power

 

failure.

 

This

 

data

 

is

 

restored

 

as

 

soon

 

as

 

the

 

power

 

supply

 

is

 

restored.

 

The

 

EQUALIS

 

user

 

interface

 

includes

 

a

 

240

 

x

 

128

 

pixel

 

backlit

 

graphic

 

display,

 

a

 

20

key

 

keyboard

 

and

 

Stop

 

and

 

Start

 

buttons.

 

The

 

electronic

 

indicator

 

S

 

EQUALIS

 

depot

 

version

 

consists

 

of

 

a

 

housing

 

composed

 

of

 

two

 

elements.

 

It

 

is

 

located

 

at

 

the

 

loading

 

point.

 

It

 

consists

 

of

 

two

 

boxes:

 

‐ 

The

 

Calculator

 

Module

 

(CM

 

module),

 

‐ 

The

 

Hydraulic

 

Module

 

(HM

 

module)

 

for

 

the

 

output

 

control.

 

The

 

electronic

 

indicator

 

is

 

supplied

 

with

 

230VAC

 

or

 

24VDC,

 

It

 

is

 

equipped

 

to

 

communicate

 

with

 

external

 

supervision

 

systems.

 

 

Содержание ZCM17

Страница 1: ...02 2018 Edition 1 19 U518156 en REV0 MASTER METER Description Operation Maintenance ...

Страница 2: ...opean ATEX Directive Revision history 2018 02 09 Rev 0 Creation Support and Contact Information Service department Avenue de Verdun CS60129 Tel 33 0 9 80 80 04 02 Email service satam eu Manufacturing facility Avenue de Verdun CS 60129 14700 Falaise France Tel 33 0 2 31 41 41 41 Fax 33 0 2 31 40 75 61 Email xxx satam eu Headquarters and Sales department Paris Nord 2 Bat Le Gauguin 47 allée des Impr...

Страница 3: ...ronic register EQUALIS S 7 C Mechanical register 8 D Rate of flow indicator 9 4 Narrative Description 10 5 Periodic Servicing 10 6 Cleaning 10 7 Meter Calibration Inspection Weight and Measures 11 A Adjustment Procedure with transmitter AB 21 11 B Adjustment Procedure with EQUALIS S 12 8 Technical data of ZCM17 mastermeter 16 A Technical data ZCM17 with mechanical register 16 B Technical data ZCM ...

Страница 4: ...uipment for fuels and petroleum products ZCM 17 is a working standard that can be used regularly to check and calibrate measuring instruments or measuring systems 2 General arrangement of ZCM17 A Version with electronic register Release valve Electronic register Pressure gauge Release valve Drainage pump Connecting pipe PD meter Connection to flexible hose ...

Страница 5: ...V0 B Version with mechanical register optional supply Isolating valve Release valve Temperature probe Pressure gauge Mechanical register Drainage pump Release valve Flowrate indicator PD meter Connection to flexible hose Connecting pipe ...

Страница 6: ...other by rods 8 and 2 steel covers 9 and 10 Measuring principle The product enters the measuring chamber following the direction of the arrow The rotor and blades assembly 1 2 is set in motion by the pressure of the liquid on blades A certain amount of liquid 3 is held between 2 blades and then directed to the discharge manifold The volume of liquid measured at each rotation is therefore equal to ...

Страница 7: ...ns essential to product loading or unloading EQUALIS is designed to be used in an explosive atmosphere with different protection modes in accordance with directive ATEX 94 9 CE It is designed to ensure the data backup of the current deliveries in the event of a power failure This data is restored as soon as the power supply is restored The EQUALIS user interface includes a 240 x 128 pixel backlit ...

Страница 8: ...eatured on this ticket is recognised by legal metrology authorities Dual channels for pulses EQUALIS S may be connected to 1 or 2 pulse transmitters Where 2 pulse transmitters are connected EQUALIS S displays the total volume from these two 2 counters Systematically for this these transmitter s the EQUALIS S counts stores and compares the two pulse channels for each transmitter with a phase shift ...

Страница 9: ...tted with a mechanical register the rate of flow indicator is an external module located at the bottom of the register The physical unit of the flow must be define at the order of the master meter When fitted with a electronic register the flow rate value is directly displayed on the register without the need of any additional module ...

Страница 10: ...by the meter to be tested Adjust the meter correction coefficient Start a new delivery to confirm the correction Use the drainage hand pump to empty the ZCM17 to limit pollution when disconnecting or testing with a new fluid Disconnect the ZCM17 hose 5 Periodic Servicing As a general rule a periodic maintenance of at least once a year is recommended Service operations must be carried out by a Weig...

Страница 11: ...remove cover A Move roller 5 by turning screw 6 using spanner C until the roller hole is aligned with the 2 holes on the support 15 Insert pin B as shown on the diagram Turn the screw right clockwise to increase the quantity of product in the gauge Turn the screw left anticlockwise to decrease the quantity of product in the gauge One turn of the screw 6 Correction of 1 Pin B SATAM ref 359809 Spann...

Страница 12: ...02 2018 Edition 12 19 U518156 en REV0 B Adjustment Procedure with EQUALIS S ...

Страница 13: ...02 2018 Edition 13 19 U518156 en REV0 ...

Страница 14: ...02 2018 Edition 14 19 U518156 en REV0 ...

Страница 15: ...02 2018 Edition 15 19 U518156 en REV0 ...

Страница 16: ...0 DN80 3 ZCM17 150 DN100 4 ZCM17 250 DN150 6 ZCM17 330 DN200 8 End connection style Flanges ASA 150 RF Coating Acrylic Epoxy coating RAL5010 Marine Epoxy coating RAL5010 option Flowmeter body Body material Ductile iron EN 5 3201 Ni resist iron EN JL3011 option Cap end cover material Carbon steel EN 1 0625 with protective coating Seal O ring material Viton Nitrile option for alcohols measurement Ex...

Страница 17: ...x 15 bar Inlet pressure max 10 bar Liquid temperature min max 10 C 90 C 14 F 194 F Working flow rate min max Model m3 h L mn USGPM ZCM17 24 2 4 24 40 400 10 5 105 ZCM17 48 4 8 48 80 800 21 210 ZCM17 80 8 80 133 1333 36 360 ZCM17 150 15 150 250 2500 66 660 ZCM17 250 25 250 416 4166 110 1100 ZCM17 330 33 330 550 5500 145 1453 Liquid viscosity max 20 mm s MID 800 mm s at operating conditions Accuracy...

Страница 18: ...ype Display Operating volume base volume volume flowrate temperature Accessories Temperature measurement Pt100 Pressure measurement Local display Trolley version option Trolley Calibration device mounted on chassis with 4 pivoting wheels Connecting pipes between meter and hoses 2 Steel Flexible hoses Connections 3mL Loose type flangesASA 150lbs TODO type couplings CAMLOCK type couplings Model Nomi...

Страница 19: ...re not shown on this drawing Dimensions mm ZCM17 24 ZCM17 48 ZCM17 80 ZCM17 150 ZCM17 250 ZCM17 330 A 600 600 1100 1100 1400 Please contact Satam for dimensions and weight B 1100 1100 1199 1250 1200 C 1050 1050 1419 1419 1800 D 520 520 520 560 700 E 870 870 870 920 980 Weight kg 218 230 300 300 450 A E B C D ...

Отзывы: