REV0
7.
Meter
Calibration
Inspection
–
Weight
and
Measures
Current
French
legislation
stipulates:
‐
Metrological
inspection
of
the
meter
at
operation
start
‐
up.
‐
Thereafter,
annual
inspections.
A.
Adjustment
Procedure
with
transmitter
AB
21
‐
Unseal
and
remove
cover
(A)
‐
Move
roller
(5)
by
turning
screw
(6)
using
spanner
"C"
until
the
roller
hole
is
aligned
with
the
2
holes
on
the
support
(15)
‐
Insert
pin
(B)
as
shown
on
the
diagram.
‐
Turn
the
screw
right
(clockwise)
to
increase
the
quantity
of
product
in
the
gauge.
‐
Turn
the
screw
left
(anticlockwise)
to
decrease
the
quantity
of
product
in
the
gauge.
‐
One
turn
of
the
screw
(6)
=
Correction
of
1‰
Pin
B
=
SATAM
ref.
359809
Spanner
C
=
SATAM
ref.
359810
CAUTION : Do not omit to remove Pin "B" after adjustment.