32
Stand 12/2012 WBS / 10/2018 TM
TROUBLE SHOOTING AND SOLUTIONS
Errors
Possible causes
Solutions
The appliance does not
work�
Problems with the main
electricity connection.
Ambient temperature is under
10°C.
Switch off and after 5 minutes restart.
Restart, if the ambient temperature is
higher.
Warning lamp for to less
water lights up�
Water intake disturbed
Valve is damaged.
Water pressure is too low.
Check the water intake
Check valve, if necessary, let it
exchange.
The water pressure has to be at least 1
kg/cm2.
The condenser does not
work�
Not enough water.
Ice collector container is full.
Check the water supply.
Empty the container.
The condenser works, but
no ice cubes
are produced�
Leak in the cooling system.
Condenser dusty.
Kühlsystem vom Fachmann überprüfen
lassen.
Kondensator staubfrei machen,
Lüftungsschlitze reinigen
The ice cubes do not fall
at all or only partially into
the container�
Ambient temperature or water
temperature are to low.
Valve is damaged.
Ambient temperature has to be at least
10°C and water temperature at least
7°C.
Exchange the valve.
The ice cubes always stick
together�
Storage tank is not sufficiently
cooled.
Often emptying.
Do not leave overnight in the storage
tank.
Control temperature.
Содержание EB 26
Страница 12: ...10 Stand 12 2012 WBS 10 2018 TM STROMLAUFPL NE MODEL EB 26 MODEL EB 40...
Страница 14: ...12 Stand 12 2012 WBS 10 2018 TM EXPLOSIONSZEICHNUNG...
Страница 29: ...27 Stand 12 2012 WBS 10 2018 TM CIRCUIT DIAGRAMS MODEL EB 26 MODEL EB 40...
Страница 31: ...29 Stand 12 2012 WBS 10 2018 TM EXPLODED DRAWING...
Страница 46: ...44 Stand 12 2012 WBS 10 2018 TM SCH MA LECTRIQUES MODEL EB 26 MODEL EB 40...
Страница 48: ...46 Stand 12 2012 WBS 10 2018 TM DESSIN EXPLOS...