background image

01113307R02

Order parts online
www.follettice.com

HCD/HMD710ABT, H_C1010ABT, H_C1010WBT, 
H_C1410ABT, H_C1410WBT, 

(See model number configurator on page 2 for details.)

self-contained

801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com

Horizon Elite

 Ice Machine Installation Instructions

to Ice Storage Bin Top-mount Applications

Summary of Contents for HCD710ABT

Page 1: ...10WBT H_C1410ABT H_C1410WBT See model number configurator on page 2 for details self contained 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com Horizon Elite Ice Machine Installation Instructions to Ice Storage Bin Top mount Applications ...

Page 2: ...st type environments catering and similar non retail applications WARNING To avoid a hazard due to instability of the appliance it must be fixed in accordance with the instructions Configuration Application S RIDE RIDE remote ice delivery equipment T Top mount 425 up to 425 lbs 193 kg 710 up to 675 lbs 306 kg 1010 up to 1061 lbs 482 kg 1410 up to 1466 lbs 665 kg 1810 up to 1790 lbs 812 kg 2110 up ...

Page 3: ...onnections 7 Ice Transport Tube Installation 7 Air cooled ice machines only 8 Water cooled ice machines only 8 Internal Connections 9 Ice transport tube 9 Potable water and drain lines 9 Power cord 9 Power cord 9 Cooling Lines 10 Ice transport tube 10 Potable Water and Drain Line 10 Cooling lines and power 10 Power cord 11 Power cord 11 Front Cover 12 Install cover 12 Start Up 12 ...

Page 4: ... 710 1010 1410 BIN TOP MOUNT 1 Unpack Carefully unpack and inspect the contents of your Follett ice machine 1 1 Unpack Ice Machine 7 16 7 16 DO NOT TILT ICE MACHINE TO ACCESS BOLTS COMPRESSOR DAMAGE WILL RESULT ...

Page 5: ..._C1010 1410 A W BT 208 230 60 Requires a 15A dedicated circuit HCD HMD710ABT 115 60 Requires dedicated 15A circuit H_E1010 1410 A W HS 230 50 H_E1000A W requires 15A circuit 1 50 mm2 wire H_E1400 A W HS 230 50 1 20 amps H_E1400A W requires 20A circuit 4 00 mm2 wire Plug must be provided by end user must conform to standard EN 60 335 2 24 of the end destination Potable Water Supply 3 8 push in inte...

Page 6: ...nt or change the drain fitting Replace back panel prior to mounting the docking assembly Docking station must be secured in accordance with these instructions to ensure ice machine stability Ventilation openings in the louvered docking station should be clear of obstruction Failure to do so could result in damage to equipment Plug must be accessible after final installation Remove protective tape ...

Page 7: ...r 160 F 71 C Install supplied ice transport tube insulation Heat end of transport tube in cup of 160 F 71 C hot water to soften and spread with pliers before making connection to ease assembly Connect ice transport tube to coupling on louvered docking station Connect ice transport tube to shuttle actuator ...

Page 8: ... the 1 slip fitting to the 1 stand pipe drain Note Minimum 8 radius on silicone drain line Drain line from the ice machine must have at least 1 4 per foot pitch 6 4mm 0 3m Apply Petrol gel to barbed drain fitting Replace access panel Rough in ice machine potable water supply 3 8 push in connection will be made at shut off valve inside machine Remove access panel if necessary Connect the silicone t...

Page 9: ...mbly ensuring that drain tube is fully seated on barbed drain fitting Insert ice transport tube all the way into coupling and tighten nut firmly Insert potable water line into valve 5 3 Power cord 5 4 Power cord Remove twist tie Carefully pass plug thru opening and plug into wall outlet For H_E units install a suitable plug Position plate into opening and secure with supplied screw WARNING Plate m...

Page 10: ...e TDS switch on the elctrical box HIGH for extended service life LOW for low scale water Install ice machine cooling water lines to louvered docking assembly 5 7 Ice transport tube 5 8 Potable Water Line Slide ice machine into louvered docking assembly ensuring that drain tube is fully seated on barbed drain fitting Insert ice transport tube into coupling and tighten nut firmly Insert potable wate...

Page 11: ... thru opening and plug into wall outlet For H_E units install a suitable plug 5 11 Plate 5 12 TDS switch CLEANER FULL DRAIN CLOG HIGH PRES HIGH AMPS SERVICE MAINT CLEAN LOW WATER TIME DELAY SLEEP CYCLE MAKING ICE LOW BIN POWER ON CLEAN TDS HIGH LOW Position plate into opening and secure with supplied screw WARNING Plate must be securely installed to ensure proper equipment ground Set the TDS switc...

Page 12: ...operating properly after installation has been made Check each item listed and call factory immediately for assistance if you experience problems with unit NOTICE Ice machine MUST be sanitized prior to operation Consult Operation and Service Manual provided with ice machine for sanitizing instructions 7 1 Before turning on power 1 Sanitize ice bin 2 Turn on water to ice machine and check for leaks...

Reviews: