Copyright © 2018, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
05/31/18
A8239A• 800-810-WIRE (9473) • www.sargentlock.com
14
SE LP10 7000 Series Multi Point Lock
6B Inside Mounting Plate and Wire Connections (ELR)
1. Install the upper left mounting screw, #8 - 32 x 5/8 Fillister for metal door or #8 x 5/8 self-drilling
Fillister for wood doors (Figure 6F).
Note: Leave the screw loose enough to slide the ELR assembly on.
2. Snake the wire through opening in ELR assembly.
3. Slide the mounting clip of the ELR assembly underneath the installed screw and tighten it to secure
the assembly in place.
Note: Be careful not to pinch or disconnect the wire located in that area.
4. Install the remaining three (3) mounting screws: 8-32 x 5/8 Fillister for metal doors or #8 x 5/8
self-tapping Fillister for wood doors.
5. Install two (2) #8 x 1/2” self-drill screws in the bottom-most pair of holes in the mounting plate (Fig. 6F).
6. Connect 6- and 2-pin connectors from device to 6- and 2-pin connectors on reader harness
(Fig. 6B, C in previous step).
7. Connect ElectroLynx 4- and 8-pin connectors from the door harness to (black) 4- and 8-pin
connectors of the SE LP10 harness (Fig. 6D in previous step).
Fig. 6F
Detail
(2) 1/4”
self-drilling
screws
(4) #8-32 x 5/8”
Fig. 6F