5 Technical Data & Approvals
5.1 Equipment – EC601, EC602, EC651, EC620, EC630 & PX300 Control Equipment
Outline Specification
INPUT 230V
230 Volts / 0 to 16 Amps
+ / - 10%
OUTPUT 230V
RCD protected, 2 x MCB outputs of 10A & 1 x MCB
output of 16A
Separate switched channels for heating system and
charger
INPUT 12V
2 x 20A battery inputs via 2 x 4 way connectors
SOLAR INPUT
1 X Dedicated solar panel input capable of supporting 10A
of solar power input (typically 180 to 200W) via a 2 way
connector
Check the solar panel rating
plate to ensure the maximum
current is <= 10A
OUTPUT 12V
25A total output via multiple switched channels protected
by 13 fused outputs
Integrated CHARGER
Input 220-240 Volts AC +/- 10%, Frequency 50 Hz +/- 6%,
Current 3A max.
DC Output 13.6 to 14.4 Volts nominal, Current 25 Amps
max (300 Watts).
Signal INPUT
4 x Fresh water level, 4 x Waste water level, 1 x Engine
running, plus multiple vehicle connections, sensor inputs
for temperature & humidity
Fresh water negative sensed
Waste water negative sensed
Data IN / OUT
CANBUS Data communication and power to Control
Panel via 6 way connector
CI-Bus Data communication to CI-Bus enabled devices
via RJ11/12 connector
IP rating
IP31
Operating
temperature
Ambient 0 to 35° Celsius
Charger case temperature with full load 65° C Max
Automatic shutdown and restart
if overheated / overloaded
Dimensions
EC601 & EC651 PSU
Overall size (HxWxD) 180 x 305 x 135mm
Clearances 75mm above, 50mm left & right
Weight 3.8 Kg
EC620 Control Panel
Overall size (HxWxD) 93 x 180 x 32mm
Cut-out size (HxW) 82 x 165mm
Fixing centres 166mm X 26MM
Weight 150 g
EC630 Comms
Module
Overall size (HxWxD) 55 x 116 x 85mm
Weight 550g
EC640 Sensor
Overall size (HxWxD) 60 x 27 x 14mm
Weight 80g
5.2 Approvals
System: BSEN 1648-1, BSEN1648-2 compliant, BS7671: 2008 compliant
Residual Current Device: RCD 40A 30mA trip to BS EN 61008
Miniature Circuit Breakers: MCB’s type C 6000A breaking capacity to BSEN 60898
Electro Magnetic Compatibility (EMC) directive 2004/108/EC Certificate CE20071224-1
Integrated Charger: BS EN 60335-1/2.29, 2006/95EC, IEC61000-3.2/3:1995, 1.
Low Voltage Directive: 2006/95EC TUV-014900-A1, EN55022, Class B, EN55024/ Level 2