62
Indoor Mode:
When the water temperature is 2ºF greater than set temperature the
circulation pump and ozone generator will turn off for 3 hours.After 3 hours the circulation
pump and ozone generator will turn on again for 1 hour but pump 1 will not operate in the
indoor mode.This cycle will keep repeating.When the circulation pump and ozone generator
are off,“SSEt” and the water temperature are alternately displayed on the panel (SSEt=summer
setting).The circulation pump turns on automatically if the water temperature drops below
1ºF of the set temperature. Indoor mode is activated by moving Jumper #8 to the right
position. Check with your Saratoga dealer for further information.The Indoor Mode does
not apply to the Polo,Adelphi, or Putnam models.
“...” (3 dots flashing):
• The filter(s) may be plugged. Remove filter(s) and clean.
• The amount of water flow may be inadequate. Make sure the water level is correct.
• A pressure switch may have malfunctioned.
Note:
If the open pressure switch error persists for more than 5 minutes, the circulation
pump output will enter an open pressure switch error cycle which consists of stopping the
circulation pump for 10 seconds, then start the circulation pump for 5 minutes.The cycle
will repeat three times prior to a final power down of the circulation pump. If any manual
key is pressed the system will restart three cycles.
“122ºF” or “32ºF”:
Open sensor (spa is deactivated):The main temperature sensor is nonfunctional.This
must be repaired only by a Dealer or service organization.
“SSEt” Summer Setting:
The Summer Set mode has been activated.The water temperature is 2ºF above the set
temperature.The Summer Set Mode will shut off after the water temperature is 1ºF
below the set temperature.The “SSEt” does not apply to the Polo,Adelphi, or Putnam
models.A “
▲
” will flash below the filter icon on these models’ control panel.
“HL” or “...” (3 Dots Flashing) with red light (located on PC board):
Overheat protection (spa is deactivated): If a malfunction occurs and the spa water
reaches 112ºF, the system will completely shut down. In such a condition, DO NOT
ENTER THE WATER.Turn off all power to the spa and contact your Dealer or service
organization.
Temperature Flashing:
Power to spa has been interrupted. Press any key on panel and temperature should
stop flashing.Temperature may also flash when spa has overheated. In such a case,
contact your Dealer and
DO NOT ENTER WATER.