Diagnostic Display Messages on Main Control Panel
Smart Winter Mode / Flashing
▲
above filter icon
This system prevents the water from freezing in the plumbing or the pumps.An onboard
sensor continuously checks the ambient air temperature in the control pack. If at any time
the temperature falls from a range of 43ºF the Smart Winter Mode will be activated for the
next 24 hours, even if the temperature returns to above 43ºF. During this Smart Winter
Mode the range of temperature will determine the frequency of the pumps operation.The
colder the ambient temperature, the more frequently the pumps will run.The time range will
vary from every 15 minutes to every 2 hours.When the pumps are operating because of this
feature, the filter cycle icon on the display will flash. No corrective action is necessary.
Summer Setting Mode / “SSEt”
Your spa is equipped with this feature to prevent heat build up.The “SSEt” does not apply to the
Polo,Adelphi and Putnam.A “
▲
” will flash below the filter icon on these models’ control panel.
Standard (Outdoor) Mode:
When water temperature is 2ºF greater than set
temperature, the circulation pump and ozone generator will turn off for 3 hours.After 3
hours the circulation pump and ozone generator will turn on again for 1 hour and pump 1
will run for 1 hour then turn off again for 3 hours; this cycle will keep repeating.When the
circulation pump and ozone generator are off “SSEt” and the water temperature are
alternately displayed on the panel (SSEt = summer setting).The circulation pump turns on
automatically if the water temperature drops below 1ºF of the set temperature.
Operations Trouble Shooting Guide Cont...
Problem
Probable Cause
Solutions
Spa jets/pump(s) • Normal power filtration cycle
• No action necessary
turn on
automatically
• Summer Setting mode cycle activated
• No action necessary
• Smart Winter mode cycle activated
• No action necessary
Not able to
• Panel may be locked
• Hold down blower key until “Uloc”
operate main
appears on the digital display
control panel
• Panel may have malfunctioned
• Contact your dealer
Water does
• Bad water chemistry
• Balance water
not clear up
• Dirty filter cartridges
• Clean or replace filters
• Ozone generator not operating or
• Locate ozone generator, look for
ozone chip needs replacement
ultraviolet light to be illuminated
through window on ozone generator
• Bromine/chlorine residual levels
• Adjust Bromine/chlorine levels.
too low
Shock if necessary. May have to
replace water