6
Getting Star
ted
Setting Up and Making Adjustments Using a Monitor
■
Using the Camera Control Unit
(VAC-70: Separately ordered)
Camera can be controlled remotely during setting or adjustment.
• Please refer to the instruction manual for VAC-70.
Button operations with VAC-70 are the same as with the unit.
■
Opening the dome cover and setting up the camera
using the buttons on the circuit board
Place the dome cover back once you have finished settings.
• See the INSTALLATION MANUAL supplied with the unit.
Checking the settings screen or camera angle
1
SET button
Press and hold for about 1 second for the main menu to appear.
2
Select button
• Press up, down, left, right to select an item on the settings screen or change a
setting value.
• The pan/tilt and zoom functions can be operated using the Select button during
live mode (with no settings screen displayed).
Press the SET button to switch over between pan/tilt and zoom operations.
VAC-70
RG-6U (5C-2V) cable,
300 m max.
BNC type
Video in
VIDEO
OUT
CAMERA
<Pan/Tilt operations>
Pan:
Press
d
(LEFT) or
c
(RIGHT)
Tilt:
Press
j
(UP) or
l
(DOWN)
<Zoom operations>
Wide:
Press
d
(LEFT)
Tele:
Press
c
(RIGHT)
UP
DOWN
LEFT
RIGHT
SET
GND
MONITOR
OUT
1
2
Checking the settings screen or
camera angle on a portable monitor
Connect the MONITOR OUT pin and the GND
pin on the circuit board to a monitor using an
alligator clip cable.
(It is also possible to connect a monitor using
the MONITOR OUT connector.)
Note:
Do not touch the camera unit except
when settings and adjustments are
necessary.
When the power is turned on, the camera
address (ADDRESS), and protocol
(CONTROL) and baud rate (BAUD RATE)
will be displayed about for 5 seconds on
the monitor screen.
When <PRIVACY MASK> is “ON”,
background of the monitor is shown in
black.
ADDRESS
CONTROL
BAUD RATE
1
485S
19200
Example
L5BL2_BM2_US_XE(GB).book 6 ページ 2006年6月14日 水曜日 午後12時56分