![Sanyo VCC-P9574S Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/sanyo/vcc-p9574s/vcc-p9574s_instruction-manual_363496046.webp)
45
Configuring the Communication Settings <OPTION>
The camera can be operated remotely by connecting a hard disk recorder or controller as a communication device. You need to
configure the conditions for the communication to function.
1
Select <CONTROL> and specify the protocol for
controlling the camera.
COAX
: Coaxial superposition (SANYO: using coaxial cable)
• SSP, Hi-speed SSP and PELCO-C are supported.
Switching among the three is automatic.
485S
: RS-485 (SANYO)
• Both SSP and Hi-speed SSP are supported. Switching
between the two is automatic.
485P
: RS-485 (PELCO-D)
2
For advanced settings (485S or 485P), press the
SET button.
R
The “CONTROL SETTING” screen appears.
• Advance to step
5
if you have selected “COAX”.
3
Select <BAUD RATE> and specify the
communication speed.
Setting Protocol for Camera Controller <CONTROL>
·OPTION
SET
CAMERA
PRESET POSITION
AUTO MODE
AUTO RETURN
ALARM
PASSWORD
LANGUAGE
·OPTION
PRESET
MENU
SET y
1 y
SEQ y
OFF
SET y
SET y
SET y
SET y
OFF
END
OPTION
TITLE
PRIVACY MASK
·CONTROL
ADDRESS
ALARM LINE OUT
PRESET
MENU
OFF
SET y
COAX
1
OFF
OFF
BACK
R
R
·CONTROL
OPTION
TITLE
PRIVACY MASK
·CONTROL
ADDRESS
ALARM LINE OUT
OFF
SET y
COAX
1
OFF
• Select from: 19200, 9600, 4800, 2400
·BAUD RATE
CONTROL SETTING
·BAUD RATE
TERMINATE
19200
OFF
For accessing the main menu, see pages 7 – 8.
L5BL2_BM2_US_XE(GB).book 45 ページ 2006年6月14日 水曜日 午後12時56分