29
Indoor Unit
SAP – K121GJA
Outdoor Unit
SAP – C121JA
220V Single Phase 60Hz
RATING CAPACITY
3.40 kW
AIR FLOW RATE
470 m
3
/h
EVAPORATOR
CONDENSER
ENT. TEMP. °C
OUTDOOR AMBIENT TEMP. °C
W.B.
D.B.
30
35
40
43
TC
3.13
2.98
2.80
2.58
CM
1.01
1.09
1.13
1.31
21
SHC
2.07
1.99
1.90
1.79
15
23
SHC
2.31
2.23
2.13
2.02
25
SHC
2.54
2.46
2.36
2.25
27
SHC
2.77
2.69
2.59
2.48
29
SHC
3.00
2.92
2.80
2.58
31
SHC
3.13
2.98
2.80
2.58
TC
3.36
3.20
3.00
2.76
CM
1.04
1.12
1.16
1.34
21
SHC
1.84
1.76
1.66
1.55
17
23
SHC
2.07
1.99
1.89
1.78
25
SHC
2.30
2.22
2.13
2.01
27
SHC
2.53
2.45
2.36
2.24
29
SHC
2.76
2.68
2.59
2.47
31
SHC
3.00
2.91
2.82
2.71
TC
3.57
#
3.40
3.20
2.94
CM
1.07
1.15
1.20
1.38
21
SHC
1.59
1.51
1.41
1.30
19
23
SHC
1.82
1.74
1.64
1.53
25
SHC
2.05
1.97
1.88
1.76
27
SHC
2.28
2.20
2.11
1.99
29
SHC
2.51
2.43
2.34
2.22
31
SHC
2.74
2.66
2.57
2.46
TC
3.78
3.60
3.39
3.12
CM
1.10
1.18
1.23
1.42
23
SHC
1.56
1.48
1.39
1.28
21
25
SHC
1.79
1.71
1.62
1.51
27
SHC
2.03
1.95
1.85
1.74
29
SHC
2.26
2.18
2.09
1.97
31
SHC
2.49
2.41
2.32
2.20
TC
4.01
3.78
3.54
3.29
CM
1.13
1.21
1.27
1.45
23
25
SHC
1.52
1.43
1.33
1.24
27
SHC
1.75
1.66
1.57
1.47
29
SHC
1.98
1.89
1.80
1.70
31
SHC
2.21
2.12
2.03
1.93
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM :
Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.