30
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
220V Single phase 60Hz
Rating Conditions
Running Amps.
A
0.15
0.27
3.78
4.2
Power Input
kW
0.031
0.060
0.799
0.89
Full Load Conditions Running Amps.
A
0.15
0.27
4.58
5.0
Power Input
kW
0.031
0.060
0.979
1.07
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91GJA
Outdoor Unit
SAP – C91JA
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
220 – 240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.17
/
0.18
0.24
/
0.25
3.49
/
3.37
3.9
/
3.8
Power Input
kW 0.034 / 0.040
0.052 / 0.060
0.754 / 0.790
0.84
/
0.89
Full Load Conditions Running Amps.
A
0.17
/
0.18
0.24
/
0.25
4.49
/
4.27
4.9
/
4.7
Power Input
kW 0.034 / 0.040
0.052 / 0.060
0.964 / 0.990
1.05
/
1.09
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91GJA
Outdoor Unit
SAP – C91GA
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
220 – 240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.13
/
0.14
0.24
/
0.25
2.63
/
2.61
3.0
/
3.0
Power Input
kW 0.026 / 0.031
0.052 / 0.060
0.562 / 0.589
0.64
/
0.68
Full Load Conditions Running Amps.
A
0.13
/
0.14
0.24
/
0.25
3.33
/
3.21
3.7
/
3.6
Power Input
kW 0.026 / 0.031
0.052 / 0.060
0.712 / 0.739
0.79
/
0.83
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K71GJA
Outdoor Unit
SAP – C71GA
Все каталоги и инструкции здесь: