A. TEST PROCEDURES
COMPONENT
CHECKOUT PROCEDURE
RESULT
1) Check for resistance : Across the filament
Normal reading :
terminals of the Magnetron with an
Less than 1 Ohm.
Ohm-Meter on R x 1 scale.
2) Check for resistance : Between each filament
Normal reading :
terminal of the Magnetron and the chassis
Infinite Ohms.
ground with an Ohm-Meter on highest scale.
1) Measure the resistance :
Normal readings :
With an Ohm-Meter on R x 1 scale.
a. Primary winding :
Approximately 1.53 Ohms.
b. Filament winding :
Less than 1 Ohm.
c. Secondary winding :
Approximately 97.2 Ohms.
2) Measure the resistance :
Normal readings :
With an Ohm-Meter on highest scale.
a. Primary winding to ground.
Infinite Ohms.
b
Filament winding to ground.
Infinite Ohms.
Note
: Remove varnish of
measured point.
Filament Windings
Primary
Windings
Secondary
Windings
6. TEST PROCEDURES AND TROUBLESHOOTING
CAUTION
- DISCONNECT THE POWER SUPPLY CORD FROM
THE WALL OUTLET WHENEVER REMOVING THE
CABINET FROM THE UNIT. PROCEED WITH THE
TESTS ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE LEAD
WIRES FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE FIGURE 3)
Figure 3
Figure 4
Figure 5
Figure 6
Ohm-Meter
Ohm-Meter
Ohm-Meter
- 4 -
HIGH-VOLTAGE
TRANSFORMER
MAGNETRON
Содержание EM-V3410WS
Страница 20: ... 19 CONTROL CIRCUIT BOARD Part No 617 237 4116 47100 ...
Страница 22: ... 21 9 OVERALL CIRCUIT DIAGRAM ...
Страница 23: ......
Страница 24: ...FEBRUARY 2001 Printed in Singapore SANYO Electric Co Ltd Osaka Japan ...