E. REMOVING FUSE
Remove the 8A Fuse with a screwdriver.
NOTE
--
When replacing the 8A Fuse, be sure to use an exact
repair part.
--
If the 8A Fuse blows immediately, check the Primary
Interlock Switch, the Relay 2 (on the Control Circuit Board)
and the Interlock Monitor Switch according to,
“CHECKOUT PROCEDURE
FOR SWITCHES”
on page 6.
And make sure to check the microwave energy leakage
according to,
“1. ADJUSTMENT
PROCEDURES”
on page
1, when the Primary Interlock Switch, the Relay 2 or the
Interlock Monitor Switch is adjusted or replaced.
--
If the Primary Interlock Switch, the Relay 2 and the Interlock
Monitor Switch operate properly, determine which of the
followings is defective : Control Circuit Board, Blower Motor,
High Voltage Transformer, High Voltage Capacitor, High
Voltage Diode or Magnetron.
F.
REMOVING POWER AND CONTROL CIRCUIT BOARD
(See exploded view on page 18 and Figure 14)
(1) Remove the Connector S1, S102 and the Connector for
the Relay 2 from the Control Circuit Board.
(2) Remove 1 screw securing the Control Panel complete to
the Oven Cavity.
(3) Remove the FPC Connector from the Connector S101
while grasping up both lever ends of the plastic fastener.
(4) Remove 2 screws securing the Control Circuit Board to
the Control Base.
(5) Lift up the Control Circuit Board from its lower side and
take it out from the Control Base.
G. REMOVING TOUCH KEY BOARD
(Figure 15)
After removing the Control Circuit Board :
(1) Remove Control Base while lifting it up at the right side
and take it out from the Control Frame.
(2) Remove Control Sheet which is glued to Touch Key Board.
(3) Remove the Touch Key Board which is held on the Control
Frame with the adhesive tape.
Control Frame
- 13 -
Control Sheet
Touch Key
Board
Figure 15
Figure 14
Control Frame
Control Base
Содержание EM-V3410WS
Страница 20: ... 19 CONTROL CIRCUIT BOARD Part No 617 237 4116 47100 ...
Страница 22: ... 21 9 OVERALL CIRCUIT DIAGRAM ...
Страница 23: ......